LG LSU090HSV4 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
23
LG Air Conditioning Systems
Specication Unit LMAN097HVP LMAN127HVP
Capacity
Cooling Btu/h 9,000 11,200
Heating Btu/h 10,400 13,300
Power
Voltage V, Ø, Hz 208/230-1-60 208/230-1-60
Power/Communication Wiring
4
No. x AWG 4 x 18 4 x 18
Operating Range
Cooling °F WB 57 ~ 77
57 ~ 77
Heating °F DB
57 ~ 81
57 ~ 81
Fan
Type Turbo Turbo
Motor Output x Qty W 24 x 1 24 x 1
Motor/Drive BLDC BLDC
Airow (H/M/L) CFM 272/208/155 314/258/198
Unit Data
Rated Amps A 0.2 0.2
Sound Pressure Level (H/M/L)
3
dB(A) 39/35/31 42/38/34
Dimensions (WxHxD) in 23-5/8 x 23-5/8 x 5-25/32 23-5/8 x 23-5/8 x 5-25/32
Weight (Net/Shipping) lbs 32/37 32/37
Piping
Liquid in 1/4 1/4
Vapor in 3/8 3/8
Drain (OD, ID) in 27/32, 5/8 27/32, 5/8
Controller Supplied AKB73635607 AKB73635607
Specication Unit LAN090HSV4 LAN120HSV4 LAN180HSV4
Capacity
Cooling Btu/h 9,000 12,000 18,000
Heating Btu/h 10,400 13,800 20,800
Power
Voltage V, Ø, Hz 208/230-1-60 208/230-1-60 208/230-1-60
Power/Communication Wiring
4
No. x AWG 4 x 18 4 x 18 4 x 18
Operating Range
Cooling °F WB 57 ~ 77 57 ~ 77 57 ~ 77
Heating °F DB 59 ~ 81 59 ~ 81 59 ~ 81
Fan
Type Cross Flow Cross Flow Cross Flow
Motor Output x Qty W 14.4 x 1 14.4 x 1 76.0 x 1
Motor/Drive BLDC BLDC BLDC
Airow (H/M/L) CFM 247/230/212 335/318/300 572/501/434
Unit Data
Rated Amps A 0.2 0.2 0.3
Sound Pressure Level (H/M/L)
3
dB(A) 33/30/27 39/36/31 37/33/28
Dimensions (WxHxD) in 34-13/16 x 11-1/4 x 8-1/16 34-13/16 x 11-1/4 x 8-1/16 40-9/16 x 12-3/4 x 9-11/16
Weight (Net/Shipping) lbs 24/29 24/29 32/39
Piping
Liquid in 1/4 1/4 1/4
Vapor in 3/8 3/8 1/2
Drain (OD/ID) in 27/32, 5/8 27/32, 5/8 27/32, 5/8
Controller Supplied AKB73835317 AKB73835317 AKB73835317
Art Cool Mirror
Art Cool Gallery
MULTI F INDOOR UNITS
Note:
1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.
2. Rated cooling capacity obtained with air entering the indoor unit at 80˚F dry bulb (DB) and 67˚F wet bulb (WB) and outdoor ambient conditions of 95˚F dry bulb (DB) and 75˚F wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70˚F dry bulb (DB) and 60˚F wet bulb (WB) and outdoor ambient conditions of 47˚F dry bulb (DB) and 43˚F wet bulb (WB).
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.
4. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.
5. Due to our policy of innovation, some specifications may be changed without notification.
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 67 68

Comments to this Manuals

No comments