SEASONAL WIND AND CAUTIONS IN WINTER
41
ENGLISH
Model Designation
Indoor unit
Outdoor unit
Airborne Noise Emission
The A-weighted sound pressure emitted by
this product is below 70 dB.
** The noise level can vary depending on the
site.
The figures quoted are emission level and are
not necessarily safe working levels. Whilst
there is a correlation between the emission
and exposure levels, this cannot be used reli-
ably to determine whether or not further pre-
cautions are required. Factor that influence
the actual level of exposure of the workforce
include the characteristics of the work room
and the other sources of noise, i.e. the num-
ber of equipment and other adjacent process-
es and the length of time for which an opera-
tor exposed to the noise. Also, the permissi-
ble exposure level can vary from country to
country. This information, however, will
enable the user of the equipment to make a
better evaluation of the hazard and risk.
1 The height of H frame must be more
than 2 times the snowfall and its width
shall not exceed the width of the prod-
uct. (If width of the frame is wider than
that of the product, snow may accumu-
late)
2 Don't install the suction hole and dis-
charge hole of the Outdoor Unit facing
the seasonal wind.
SM AWR09 BN0
Serial number
Indoor
Detailed product type
AQ : Deluxe SQ : Standard
AH* : Panel type color_Gallery(1), Silvr(V),
Red(E), Gold(G), White Silver(H)
AW* : Mirror type color_Mirror(R), Silver(V),
White(W)
AH : Ceiling cassette
L : Low static
No mark for Standard Inverter indoor units
Nominal Capacity
EX) 9,000 Btu/h Class '09'
24,000 Btu/h Class '24'
Type
Model Type
M : Multi Indoor unit
C : Common Indoor unit for
Universal and Multi
S : Wall mounted/ARTCOOL Mirror
J : Wall mounted A : ARTCOOL Panel
T : Cassette B : Duct V : Floor-ceiling
Q : Console
Chassis name
MU4
M27
Type of refrigerant
M : R410A R : R32
Nominal capacity
Ex) 18,000 Btu/h Class '18'
Serial number
Outdoor unit chassis name
Indicates that this is multi system
outdoor unit
Ex)
MU3 : Connectable max. 3 indoor units
MU4 : Connectable max. 4 indoor units
U4 2
FM
40 U3 2AH
Model type
Outdoor unit chassis name
Serial number
H : Heat pump
Type of refrigerant
A : R410A
Nominal capacity
Ex) 48,000 Btu/h Class '48'
Model type
FM : Inverter multi ststem of
Distributor Box type
1,MFL68883815,영영 17. 12. 16. 영영 9:57 Page 41