FUNCTION
ENGLISH
14/16/18/21(1Ø) kBtu/h 40(1Ø) kBtu/h
24/27/30(1Ø) kBtu/h
DIP-SW
SW01N
DIP SW2
Forced Cooling Operation
Adding the refrigerant in winter.
Setting Procedure
1 Set the Dip Switch as follow after shutting
the power source down.
2 Reset the power.
3 Check that the Red LED of PCB is on dur-
ing work.
(The indoor unit is operated by force.)
4 Add the specific amount of refrigerant.
- When the green LED of PCB is on,
compressor is going to be off because
of low pressure.
- You should return the Dip Switch to
operate normally after finishing the
operation.
CAUTION
!