THE INDOOR UNIT INSTALLATION
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling
board
150mm
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Air Conditioner body
Keep the length of 15~18mm
between the air conditioner
bottom surface and the ceiling
surface
Adjust the
same height
The following parts is option.
Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10
Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole-core drill.
Wall
Indoor
Outdoor
5~7mm
CAUTION
Tighten the nut and bolt to prevent unit
falling.
!
Maintenance
drain port
Upward
routing
not allowed
Pipe clamp
Indoor unit
300mm or less
Indoor Unit Drain Piping
- Drain piping must have down-slope (1/50 to
1/100): be sure not to provide up-and-down
slope to prevent reversal flow.
- During drain piping connection, be careful
not to exert extra force on the drain port on
the indoor unit.
- The outside diameter of the drain connection
on the indoor unit is 32mm.
- Be sure to execute heat insulation on the
drain piping.
- Install the drain raising pipes at a right
angle to the indoor unit and no more than
300mm from the unit.
Piping material: Polyvinyl chloride pipe VP-
25 and pipe fittings