HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
OTL Report No. 116-F-36-5
B-VENT
MPB-33/35/40/45 SERIES
MODELS
A French manual is available upon request. Order P/N 875,031CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 875,031CF.
Millivolt Models
P/N 875,031M REV. A 02/2006
B-VENT GAS FIREPLACES
MPB3328CNM
MPB3328CPM
MPB3530CNM
MPB3530CPM
MPB4035CNM
MPB4540CNM
MPB3328CNE
MPB3530CNE
MPB4035CNE
MPB4540CNE
Electronic Models
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
infl ammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bati-
ment où vous vous trouvez.
Evacuez la piéce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournis-
seur de gaz.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell
gas:
DO NOT light any appliance.
DO NOT touch any electrical switches.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by a
qualifi ed installer, service agency or gas supplier.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
WARNINGS
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
If small children are present in the home, it is
recommended that this appliance be fi tted with
a screen door or screen panel kit. See Page 17
for ordering information.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - MPB-33/35/40/45 SERIES

HOMEOWNER'S CARE ANDOPERATION INSTRUCTIONSOTL Report No. 116-F-36-5B-VENTMPB-33/35/40/45 SERIESMODELSA French manual is available upon request. O

Page 2 - TABLE OF CONTENTS

10NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Glowing Embers, Vermiculite, Decorative Volcanic Stone And Log Placement Instructions:Step 1. S

Page 3 - AVERTISSEMENT

11NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.MPB-3328 LOG PLACEMENT1Position the individual logs as shown below. Logs should be placed in the

Page 4 - SIT Millivolt Gas Valve

12NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.MPB-3530 LOG PLACEMENT1Position the individual logs as shown below. Logs should be placed in the

Page 5 - Spillage Test

13NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.MPB-4035 & MPB-4540 LOG PLACEMENT1Position the individual logs as shown below. Logs should

Page 6

14NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.WIRING DIAGRAMSWiring diagrams are provided here for reference purposes only. This information

Page 7 - IMPORTANT

15NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Remote Control Kit, StandardCat. No. Model No. DescriptionH0249 RCL Remote Control System (Stan

Page 8 - Burner Adjustments

16NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Arch Door Kit - Polished BrassCat. No. Model Models-Where Used98L05 ADK33CPB MPB-332826M43 ADK3

Page 9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.17ARCH DESIGN SCREEN DOOR KITSCat. No. Model Description Where UsedH0858 AD35C 35” Arch Doors, Cha

Page 10 - Placement Instructions:

18NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Decorative Arch Screen Panel Kit Cat. No. Model ModelH3593 DASPK35TI 35” Dec. Arch Screen Panel

Page 11 - MPB-3328 LOG PLACEMENT

19NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVEWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS

Page 12 - MPB-3530 LOG PLACEMENT

2NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.CONGRATULATIONS!In selecting this Lennox B-Vent Gas Appliance you have chosen the fi nest and most

Page 13 - Catalog Number

20NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SI

Page 14 - SIT Millivolt Wiring Diagram

21NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

Page 15

22NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.INSTRUCTIONS D’ALLUMAGE — ELECTRONICINSTRUCTIONS

Page 16 - Door Frame Kits

23NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEMNote: Before troubleshooting the gas control

Page 17 - Screen Panel Kit

24NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.START CHECK• Turn Off Gas Supply.• Ensure Valve Switch Is In ON Position.• Disconnect Control Ha

Page 18 - (lower grille shown)

25NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Item # DescriptionMPB-3328 MPB-3530 MPB-4035 MPB-4540Part No. Qty. Part No. Qty. Part No. Qty. P

Page 19 - MILLIVOLT PILOT

26NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.REPLACEMENT PARTS 471254013124238940/451415933/3520211040/4533/3510232226252741434414Located Ins

Page 20 - INSTRUCTIONS D'ALLUMAGE

27NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.NOTES

Page 21 - Front View

Printed in U.S.A. © 2005 by Lennox Hearth ProductsP/N 875,031M REV. A 02/2006 Lennox Hearth Products reserves the right to make changes at any tim

Page 22 - INSTRUCTIONS D’ALLUMAGE

3NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en parti

Page 23 - TROUBLESHOOTING

4NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equ

Page 24

5NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Outside Combustion Air ControlsMany appliances are equipped, when installed, with an outside (mak

Page 25 - REPLACEMENT PARTS LIST

6NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDUREInspecting/Cleaning Burner, Logs and ControlsQuali

Page 26 - REPLACEMENT PARTS

7NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.To install the front glass enclosure panel, proceed as follows:1. Retrieve the glass door frame.

Page 27

8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Electronic Appliance CheckoutTo light the burner, refer to the lighting instruc-tions on Pages20

Page 28

9NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 10 Figure 11Figure 12Burner Flame Appearance - Model MPB-3328Burner Flame Appearance - Mod