System Set-Up
62 Air-to-Water Heat Pump
※
Some contents may not be displayed depending on DIP switch setting in the Main PCB
assembly(Heater).
Code Item Detail Remark
2A Function
Description
Value #1
Note
Default
Range
Value #2
Note
Default
Range
2B Function
Description
Value #1
Note
Default
Range
Value #2
Note
Default
Range
Value #3
Note
Default
Range
2E Function
Description
Value #1
Note
Default
Range
2F Function
Description
Value #1
Note
Default
Range
Miscellaneous setting
Determine electric heater and water heater on and off
00: Operate both electric heater and Domestic hot water tank heater
01: Operate only Domestic hot water tank heater
00
00 ~ 01
Not used
-
-
Domestic hot water heating timers
Determine following time duration : operation time of
Domestic hot water tank heating, stop time of Domestic hot
water tank heating, and delay time of sanitary tank heater
operating.
This time duration defines how long time Domestic hot
water tank heating can be continued.
30 min
5 ~ 95 min (step: 5 min)
This time duration defines how long time sanitary tank
heating can be stopped. It is also regarded as time gap
between Domestic hot water tank heating cycle.
180 min
0 ~ 600 min (step: 30 min)
This time duration defines how long time Domestic hot
water tank heater will not be turned on in Domestic hot
water heating operation.
20 min
20 ~ 95 min (step: 5 min)
Changing thermal on / off room air temp
Select Thermal on / off Temperature gap.
0
1
2
3
0
0 ~ 3
Changing thermal on / off leaving water Temp
Select Thermal on / off Temperature gap.
0
1
2
3
0
0 ~ 3
Thermal on
-0.5 °C
4 °C
2 °C
-1 °C
Thermal off
1.5 °C
6 °C
4 °C
1 °C
Thermal on
-2 °C
-6 °C
-2 °C
-1 °C
Thermal off
2 °C
4 °C
4 °C
1 °C
Comments to this Manuals