46 Air-to-Water Heat Pump
How to install sanitary water tank kit
Follow below procedures Step 1 ~ Step 5.
Step 1. Uncover the water tank kit and locate it on the wall.
Step 2. Connect the water tank kit to the main power like the below figure 2.
Step 3. Connect the water tank kit to the Main PCB assembly(Heater) like the below figure 2.
Step 4.
Connect power cord of sanitary tank heater. It is located inside of the tank. Refer to the next
page for more information.
Step 5.
Find sanitary water tank sensor. Plug it to 'CN_TH4' (Red Connector) of the Main PCB
assembly(Heater). The sensor should be mounted correctly to the sensor hole of sanitary
water tank. Like below figure. 1
Step 6. Connect the Main PCB to terminal block with wire(Part 4) like figure 3.
※ This wire is only for AHBWXXXA0 model.
Sensor mounting
Insert sensor into sensor socket and bolt it tightly.
Sanitary Water
Tank
Sanitary
Water Tank
Sensor
CN-TH4
1 2 3 4 5 6
Main Power
220-240
67
BR
Main PCB
BL
Fig. 1
Fig. 3
CH-B/HEAT(A)
Fig. 2
CAUTION