1-10.
Temperature
compensation
and
over-cool/weak-cool
compensation
circuit
1.
Temperature
compensation
at
freezing
room,
cold
storage
room
1)
GR-L197, GR-L207, GR-L247,
GR-P207,
GR-P247
2)
GR-B197, GR-B207, GR-B247,
GR-C207,
GR-C247
u
Temperature
compensation
table
by
adjustment
value
(difference
value
against
current
temperature)
Ex)
If
changing
compensation
resistance
at
a
cold
storage
room
(RCR1)
from
10
kΩ
(current
resistance)
to
18
kΩ
(modified
resistance),
temperature
at
the
cold
storage
will
increase
by
+1°C.
EXPLATION
FOR
MICOM
CIRCUIT
-50-
Freezing
room
Cold
storage
room
Resistance
value
Temperature
Resistance
value
Temperature
Remarks
(RCF1)
compensation
(RCR1)
compensation
180
kΩ
+5
°C
180
kΩ
+2.5
°C
Warmly
56
kΩ
+4
°C
56
kΩ
+2.0
°C
compensate
33
kΩ
+3
°C
33
kΩ
+1.5
°C
18
kΩ
+2
°C
18
kΩ
+1.0
°C
12
kΩ
+1
°C
12
kΩ
+0.5
°C
10
kΩ
0°C
10
kΩ
0°C
Reference
temperature
8.2
kΩ
-1
°C
8.2
kΩ
-0.5
°C
5.6
kΩ
-2
°C
5.6
kΩ
-1.0
°C
3.3
kΩ
-3
°C
3.3
kΩ
-1.5
°C
2kΩ
-4
°C2
k
Ω
-2.0
°C
Coolly
470
Ω
-5
°C
470
Ω
-2.5
°C
compensate
Comments to this Manuals