3-4.
Practical
Work
For
Heavy
Repair
TROUBLE
DIAGNOSIS
-102-
Items
Precautions
1.
Removal
of
residual
refrigerant.
1)
Remove
residual
refrigerant
more
than
5
minutes
later
after
turning
off
the
refrigerator.
(
If
not,
compressor
oil
may
leak
inside.)
2)
Remove
retained
refrigerant
slowly
by
cutting
first
high
pressure
side
(drier
part)
with
a
nipper
and
then
cut
low
pressure
side.
2.
Nitrogen
blowing
welding.
When
replacing
a
drier:
Weld
and
parts
by
blowing
nitrogen(0.1~0.2kg/cm2)
to
high
pressure
side
after
assembling
a
drier.
When
replacing
a
compressor:
Weld
and
parts
by
blowing
nitrogen
to
the
low
pressure
side.
Note)
For
other
parts,
nitrogen
blowing
is
not
necessary
because
it
does
not
produce
oxidized
scales
inside
pipe
because
of
its
short
welding
time.
3.
Replacement
of
drier.
Inserting
a
capillary
tube
Measure
distance
with
a
ruler
and
put
a
mark(12+3/-0)on
the
capillary
tube.
Insert
tube
to
the
mark,
and
weld
it
KEYPOINTING
Observe
the
sequence
for
removal
of
refrigerant.
(If
not,
compressor
oil
may
leak.)
KEYPOINTING
Welding
without
nitrogen
blowing
produces
oxidized
scales
inside
a
pipe,
which
affect
on
performance
and
reliability
of
a
product.
KEYPOINTING
Be
sure
to
check
the
inserted
length
of
capillary
tube
when
it
is
inserted.
(If
too
much
inserted,
a
capillary
tube
is
clogged
by
a
filter.)
Compressor
Low
pressure
side
Condenser
High
pressure
side
Drier
Evaporator
Release
Refrigent
Intake
Suction
1
2
1
2
Evaporator
Drier
High
pressure
side
Condenser
Refrigent
Intake
12+3
-0
Filter
*Unit:mm