8
INSTALLATION INSTRUCTION
4 Please refer to the following directions
when connecting the indoor unit and the
wired remote controller together.
1) Please connect the cables as shown in the
figure below when connecting the plug
type cable from the indoor unit’s C/BOX
and the housing type of the extension
cable.
2) When connecting Terminal Blocks of the in-
door C/BOX and the wired remote con-
troller with the extension cable, refer to the
steps below.
① Remove the screw on the cable which is
fastened to the wired remote controller’s
Terminal Block by loosening with a screw
driver.
② Remove the housing of the provided 32ft
extension cable with a cutting nipper and
peel it as shown in the figure below. (when
purchasing the extension cable at the site
directly, please peel it as shown in the fig-
ure below.)
③ Make sure each wire is securely fastened
under each screw terminal and the wires
are not in contact with each other.
④ Please connect the Terminal blocks of in-
door unit’s C/BOX and wired remote con-
troller by referring to the images and
contents shown below.
Connect the yellow(signal) part of the wired
remote controller’s terminal block and the
‘YL’ part of the indoor unit’s terminal block.
Connect the red(12V) part of the wired re-
mote controller’s terminal block and the
‘RD’ part of the indoor unit’s terminal block.
Connect the black(GND) part of the wired
remote controller’s terminal block and the
‘BK’ part of the indoor unit’s terminal block.
* In case of loosened screws or insufficient
contact between the terminal and the wire,
remote controller may not function properly.
* When the power is off on the remote con-
troller, check the connection between the
remote controller and Terminal Block.
* Use an appropriate screwdriver for tighten-
ing the terminal screws. A screwdriver with
a small head will strip the head and make
proper tightening impossible.
* Over-tightening the terminal screws may
break wires and terminal block structure.
ENGLISH