LG LK-0880HH User Manual

Browse online or download User Manual for Unknown LG LK-0880HH. LG LK-0880HH Owner's manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ENGLISH ITALIANO FRANÇAIS
êìëëäàâ üáõä
SINGLE PACKAGED AIR CONDITIONERS
INSTALLATION & MAINTENANCE INSTRUCTIONS
• Please read this instruction sheet completely before installing the product.
Installation work must be performed in accordance with national wiring standards by authorized
personnel only.
P/No.: 3828A20229P
Air Outlet Vents
Filter
Access Panel
E/Heater
Access Panel
Unit Power Wires
Control and Compressor
Access Panel
Air Intake Vents
Refresh
Air Hood
Supply
(Side)
(Rear)
Return
Front View
Rear View
50Hz
ESPAÑOL
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - ENGLISH ITALIANO FRANÇAIS

ENGLISH ITALIANO FRANÇAISêìëëäàâ üáõäSINGLE PACKAGED AIR CONDITIONERS INSTALLATION & MAINTENANCE INSTRUCTIONS• Please read this instruction sheet

Page 2 - TABLE OF CONTENTS

Check the unit nameplate for the required supply voltage. Determine if adequate electricalpower is available. Refer to application specifications.Elec

Page 3

ENGLISH11BR RD YLMAIN PCB ASMT/B 4REMOTECONTROLLERCN-THERMOSTAT21RDWHAC 24VFANHEATER1COMP1RGBKORBRWHEATER2W1YT/B 2T/B 3REMOVE JUMP WIRE WHENCONNECTING

Page 4 - 2. Dimensional Data

HIGH VOLTAGE FIELD WIRING DIAGRAM12RDWHAC 24VFANCOOLINGHEATINGCOMP 1HEATER 1RGOBBKORBRYLBLRDWHBKXWW1YHEATER 2EMER, HEATERET/B 2T/B 3REMOVE JUMP WIRE W

Page 5 - CLEARANCE 34"

ENGLISHField Installed DC Control WiringBefore installing the connecting wiring between the components utilizing a DC analogoutput/input signal and th

Page 6 - 3. Installation of Unit

14(Note)• Keep all wires away from the refrigerant pipe.• To protect the control cord from electrical noise, place DC wires at least 0.2 inch away fro

Page 7 - HORIZONTAL RETURN

The "initialization" by the MAIN CONTROLLER occurs each time the system is powered-up.the MAIN CONTROLLER performs internal self-diagnostics

Page 8 - 6. Filter Installation

1611. Test Mode ProcedureOperating the unit from the roof using the test mode.The step test mode is initiated by pressing test key(tact switch located

Page 9 - Control Box

ENGLISH17Test Mode TableTest key is available when the power is offSTEP1OXXXXXXXXXXX2OOXXXXXXXXXX3OOOXXXXXXXXX4OOOOXXXXXXXX5OOOOOXXXXXXX6OXXXXOXXXXXX7

Page 10 - 8. Electrical Wiring

1812. Trial Run ModeOperating the unit in the room withoutconcerning about set temperature.Pressing simultaneously 'Room TemperatureChecking Butt

Page 11 - Remove these wires

Use the following procedure to determine the proper adjustment of the evaporator fan for a specific application.1. Determine total system external sta

Page 12 - EMI noise

21.The following should be always observed for safety ...32. Dimensional Data ...

Page 13 - 9. Control Wiring

2015. Start-upVerify that the unit airflow rate is adjusted according to information provided in "DeterminingEvaporator Fan Adjustment" sect

Page 14 - Power wires

ENGLISH21After the unit has operated in the cooling mode for a short period of time, install pressuregauges on the gauge ports of the discharge and su

Page 15

You can do some of the periodic maintenance functions for your unit yourself; this includescleaning air filters, cleaning unit cabinet, cleaning the c

Page 16 - 11. Test Mode Procedure

ENGLISHUnfiltered air circulates through the unit's condenser coil and can cause the coil's surface tobecome clogged with dust, dirt, etc..

Page 18 - 12. Trial Run Mode

ENGLISH31. The following should be always observed for safety• Please report to or take consent by the supply authority before connecting to the syste

Page 19 - 14. Evaporator Fan Adjustment

UNIT Dimensions (Figure 1A)UNIT Dimensions (Figure 1B)4Single packaged cooling unit are designed for outdoor mounting with vertical condenser discharg

Page 20 - 15. Start-up

ENGLISHHorizontal Application Unit (Figure 1E)Rear View Showing Duct Openings For Horizontal Air FlowHorizontal Unit (Figure 1F)Rear View Showing Duc

Page 21

3-1. Inspection1) Check for damage after unit is unloaded. Report promptly, to the carrier, any damage found in the unit.Do not drop unit.2) Check the

Page 22 - Air Filters

ENGLISH1. Attaching Downflow Ductwork to The Roof Curb (below 5.0RT)Supply and return air flanges are provided on the roof curb for easy duct installa

Page 23 - Condenser coil

A. CONDENSATE DRAINA 3/4 inch male condensate drain connection is located on the corner of the unit next to the evaporatorsection access panel. A trap

Page 24

97. Installation of remote controllerENGLISH• Install the remote control box and cord correctly.• As the room temperature sensor is in the remote cont

Comments to this Manuals

No comments