LG HU143.U33 User Manual

Browse online or download User Manual for Heat pumps LG HU143.U33. LG HU091.U43 Owner's manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 87
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Original instruction
[
Representative
] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu,
Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
INSTALLATION MANUAL
AIR-TO-WATER
HEAT PUMP
P/NO : MFL68681810
ENGLISH
ITALIANO
ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 1
Page view 0
1 2 3 4 5 6 ... 86 87

Summary of Contents

Page 1 - HEAT PUMP

www.lg.comPlease read this installation manual completely before installing the product.Installation work must be performed in accordance with the nat

Page 2 - TABLE OF CONTENTS

10 Air-to-Water Heat Pump2. Installation PartThank you for choosing LG Electronics Air-to-Water Heat Pump Before starting installation, please make i

Page 3 -

Installation Manual 11ENGLISHGeneral Information3. General InformationModel InformationWith advanced inverter technology, is s

Page 4 - 4 Air-to-Water Heat Pump

12 Air-to-Water Heat PumpGeneral Information*1 : tested under Eurovent Heating condition (water temperature 30°C ’ 35°C at outdoor ambient temperature

Page 5 - Installation Manual 5

General InformationInstallation Manual 13ENGLISHIf is installed with pre-existing boiler, the boiler and should not beoperated together. If enterin

Page 6 - 1. Safety Precautions

CASE 2: Connecting DHW TankOutdoor IndoorOutdoor UnitIndoor UnitFloor heating loopFan coil unit DHWtankHot waterCity waterRadiatorHigh TemperatureRoom

Page 7 - Operation

General Information CASE 3: Connecting Solar thermal systemSolar heat sourceOutdoor IndoorOutdoor UnitIndoor UnitFloor heating loopFan coil unit DHW

Page 8 - 8 Air-to-Water Heat Pump

16 Air-to-Water Heat PumpCycle DiagramDescriptionGAS SIDEServiceValve(3 way)EEVServiceValve(3 way)Indoor UnitPlate HeatExchangerTh2Th3Water. OutWater.

Page 9 - Installation

General InformationWater cycleBasic installation (IDU + ODU) SolarThermalComponetsDHW TankFanCoilUnitUnderfloorHeatingRadiatorDHW Tank isInstalled(DHW

Page 10 - 2. Installation Part

General Information Description- Meaning is expressed based on Coolingmode.- TH3, TH4, and TH5 are connected at 6 pintype connector CN_TH3.- Heating

Page 11 - 3. General Information

General InformationParts and DimensionsIndoor unit(External)850315490490315DescriptionInstallation Manual 19ENGLISHNo Name Remark1 Control Panel Buil

Page 12 - General Information

Air-to-Water Heat Pump Installation ManualTABLE OF CONTENTSPREFACE...

Page 13 - Typical Installation Example

General Information Indoor unit(Internal)484289.648412311684.563.436.946.476 41847.820 Air-to-Water Heat Pump(unit:mm)1,MFL68681810,영영 2017. 7. 1.

Page 14 - Connecting DHW Tank

General InformationDescriptionInstallation Manual 21ENGLISHNo Name Remark1 Leaving Water Pipe Male PT 1 inch2 Entering Water Pipe Male PT 1 inch3 Ref

Page 15 - Installation Manual 15

General Information 22 Air-to-Water Heat PumpOutdoor unit(External)Supporter490DescriptionNo Name123Liquid-side Service ValveGas-side Service ValveA

Page 16 - Cycle Diagram

General InformationSupporterDescriptionNo Name123Liquid-side Service ValveGas-side Service ValveAir discharge GrillProduct HeatingCapacity : 5kW,7kW,9

Page 17 - Water cycle

General Information Control PartsControl Box : Indoor UnitDescription1Ø Electric Heater Model 3Ø Electric Heater Model24 Air-to-Water Heat PumpNo Na

Page 18 - Description

General InformationControl PanelWiring Diagram : Indoor Unit- Refer to the wiring diagram inside the control box.Circuit Diagram : Indoor Unit- Refer

Page 19 - Parts and Dimensions

General Information Wiring Diagram : Indoor and Outdoor Unit(Including Field wiring)(Indoor : Electric Heater 1Ø, Outdoor : 1Ø)26 Air-to-Water Heat

Page 20 - Indoor unit(Internal)

Installation Manual 27ENGLISHWiring Diagram : Indoor and Outdoor Unit(Including Field wiring)(Indoor : Electric Heater 3Ø, Outdoor : 3Ø)General Infor

Page 21

28 Air-to-Water Heat Pump4. Installation of Outdoor UnitThe outdoor unit of is installed outside to exchange heat with ambient

Page 22 - Outdoor unit(External)

Installation of Outdoor UnitInstallation Manual 29ENGLISHInstallation at SeasideSeasonal wind and cautions in winter1. Air conditioners should not be

Page 23 - (unit:mm)

MOUNTING TO WALL ...31 WATER

Page 24 - Control Parts

Installation of Indoor Unit30 Air-to-Water Heat Pump5. Installation of Indoor UnitThe indoor unit of is installed inside where

Page 25 - Wiring Diagram : Outdoor Unit

Installation of Indoor UnitInstallation Manual 31ENGLISHMounting to WallStep 2. After releasing five screws, detach front cover from the indoor unit.

Page 26 - 26 Air-to-Water Heat Pump

Self drilling screw can be used as alternatives of M8 ~ M11 anchorbolts. But M8 ~ M11 anchor bolts are more preferred.Step 5. Hang the indoor unit at

Page 27 - Installation Manual 27

Installation of Indoor UnitInstallation Manual 33ENGLISHAHNW16606A3, AHNW16809A3Pump model : PY-122NDDD3WARNINGSelecting a water flowrate outside the

Page 28 - Indoor Outdoor

CapacityRated flow-rate[LPM]Pump Head [m] (at rated flow-rate)Product pressuredrop [m] (Plate heatexchanger)Serviceable Head [m]Installation of Indoo

Page 29 - Installation at Seaside

Installation Manual 35ENGLISHInstallation of Indoor UnitWater Volume and Expansion Vessel PressureInside expansion vessel is i

Page 30 - Service Space

36 Air-to-Water Heat PumpInstallation of Indoor Unit Water QualityWater quality should be complied with EN 98/83 EC Directives. Requirement for res

Page 31 - Upper screw

Piping and Wiring for Outdoor UnitInstallation Manual 37ENGLISH6. Piping and Wiring for Outdoor UnitProcedures about refrigerant piping and electric

Page 32 - 32 Air-to-Water Heat Pump

Piping and Wiring for Outdoor Unit38 Air-to-Water Heat PumpStep 1. Cut the pipes and the cable.• Use the accessory piping kit or the pipespurchased lo

Page 33 - Pump model : PY-122NDDD3

Piping and Wiring for Outdoor UnitInstallation Manual 39ENGLISHConnecting Pipe to Indoor UnitConnecting pipe to the indoor unit is two steps. Read fo

Page 34 - Pressure Drop

HOW TO INSTALL DHW TANK...58 HOW TO INSTA

Page 35 - Installation of Indoor Unit

Piping and Wiring for Outdoor Unit 40 Air-to-Water Heat PumpStep 2. Tightening• Align the center of the pipes and sufficientlytighten the flare nut

Page 36 - Frost protection

Piping and Wiring for Outdoor UnitInstallation Manual 41ENGLISHThe power cord connected to the outdoor unit should be complied withIEC 60245 or HD 22

Page 37 - Refrigerant Piping

• European/International Technical Standard setting the limits for voltage changes, voltagefluctuations and flicker in public low-voltage supply syste

Page 38 - Preparation for Piping

Piping and Wiring for Outdoor UnitInstallation Manual 43ENGLISHAfter checking and confirming following conditions, start wiring work.1. Secure dedica

Page 39 - Backward

After pipes are connected and electric cables are wired, pipe forming and some tests are remained. Especially,careful attention is required while proc

Page 40 - Continuous

Piping and Wiring for Outdoor UnitInstallation Manual 45ENGLISHAir and moisture remaining in the refrigerant system have undesirable effects as indic

Page 41 - Power wire

Evacuation1. Connect the charge hose end described in thepreceding steps to the vacuum pump to evacuatethe tubing and indoor unit.Confirm the "Lo

Page 42 - Circuit Breaker Specification

Piping and Wiring for Indoor UnitInstallation Manual 47ENGLISH7. Piping and Wiring for Indoor UnitProcedures about water piping and electric wiring a

Page 43 - Installation Manual 43

Installing shut-off valve • While assembling two shut-off valves, that are found inside ‘AWHP Installation Kit(AET69364401)’, pop sound will be heard

Page 44 - Finalizing

Piping and Wiring for Indoor UnitInstallation Manual 49ENGLISHWater ChargingFor water charging, please follow below procedures.Step 1. Open all valve

Page 45 - Leakage test and Evacuation

PrefaceInstallation Manual 5ENGLISHPrefaceThis installation manual is to present information and guide about understanding, installing, and checking

Page 46 - Pressure

General ConsiderationFollowings are should be considered before beginning indoor unit wiring.• Field-supplied electrical components such as power swit

Page 47

Piping and Wiring for Indoor UnitInstallation Manual 51ENGLISHTerminal Block InformationSymbols used below pictures are as follows :- L, L1, L2 : Liv

Page 48 - 48 Air-to-Water Heat Pump

Piping and Wiring for Indoor Unit 52 Air-to-Water Heat PumpConnecting with Outdoor UnitElectric Heater Wiring123Terminal block at outdoor unitNLExte

Page 49 - Pipe Insulation

Accessories InstallationInstallation Manual 53ENGLISH8. Accessories InstallationAccessories supported by LG ElectronicsAccessories supported by 3rdpa

Page 50 - Electrical Wiring

Accessories Installation54 Air-to-Water Heat PumpThermostat is generally used to control the product by air temperature. When thermostat isconnected t

Page 51 - Terminal Block Information

Accessories InstallationInstallation Manual 55ENGLISHHow to wire thermostatFollow below procedures Step 1 ~ Step 5.Step 1. Uncover front cover of the

Page 52 - Electric Heater Wiring

56 Air-to-Water Heat PumpAccessories InstallationFinal check• DIP switch setting : Set DIP switch No. 8 to ‘ON’. Otherwise, the unit can not recognize

Page 53 - 8. Accessories Installation

Installation Manual 57ENGLISHAccessories InstallationTo establish DHW circuit, 3way valve and DHW tank kit is required. If solar thermal system is pr

Page 54 - Thermostat

Accessories Installation 58 Air-to-Water Heat PumpHow to Install DHW TankFor more detail information about installing DHW tank, please refer install

Page 55 - How to wire thermostat

Accessories InstallationInstallation Manual 59ENGLISHHow to Install DHW Tank KitFellow bellow procedures Spet 1 ~ Step 6Step 1. Find magnetic switch

Page 56 - Final check

Safety Precautions6 Air-to-Water Heat Pump1. Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instru

Page 57

Accessories Installation 60 Air-to-Water Heat PumpRelay contactorport no. assignmentELB(MCCB) port no.assignment1 32 4Note: Some models are using MC

Page 58 - How to Install DHW Tank

Accessories InstallationInstallation Manual 61ENGLISHHow to Wire DHW Tank HeaterStep 1. Uncover heater cover of the DHW tank. It is located side of t

Page 59 - How to Install DHW Tank Kit

Accessories Installation 62 Air-to-Water Heat PumpHow to Install Solar Thermal KitStep 1. Check the diameter of pre-installed pipes. (symbol Ⓐ and Ⓑ

Page 60 - DHW tank

Accessories InstallationInstallation Manual 63ENGLISHFinal Check• Flow direction : - Water should flow from water outlet of the indoor unit to DHW ta

Page 61 - How to Wire DHW Tank Heater

Accessories Installation 64 Air-to-Water Heat PumpDew Condensation• Wrong wiring can yield dew condensation on the floor. If radiator isconnected at

Page 62 - Remote Temperature Sensor

Accessories InstallationInstallation Manual 65ENGLISHThermostatConditions if Accessories are InstalledThis section describes conditions about install

Page 63 - 3WAY VALVE

Accessories Installation 66 Air-to-Water Heat PumpDHW Tank and DHW Tank Kit / Solar Thermal KitInstalling DHW tank requires following considerations

Page 64 - 14 15 16

Accessories InstallationInstallation Manual 67ENGLISHInstalling recirculation pumpWhen is used with DHW tank, it is STRONGLY recommended to install

Page 65 - Remote Air Temperature Sensor

68 Air-to-Water Heat PumpSystem Set-Up9. System Set-UpAs is designed to satisfy various installation environment, it is important to set upsystem cor

Page 66 - 66 Air-to-Water Heat Pump

Installation Manual 69ENGLISHSystem Set-UpDIP Switch InformationDescription Setting DefaultRole when centralcontroller is equipped11As MasterAs Slave

Page 67 - Water Out

Safety PrecautionsInstallation Manual 7ENGLISH• Do not install the unit on a defective installation stand.- It may cause injury, accident, or damage

Page 68 - 9. System Set-Up

70 Air-to-Water Heat PumpSystem Set-UpEmergency Operation• Definition of terms- Trouble : a problem which can stop system operation, and can be resume

Page 69 - DIP Switch Information

Installation Manual 71ENGLISHSystem Set-Up• Duplicated trouble : Option trouble with slight or heavy trouble- If option trouble is occurred with slig

Page 70 - System Set-Up

System Set-Up 72 Air-to-Water Heat PumpInstaller SettingHow to enter installer setting mode• In the menu screen, press [<,>(left/right)] butto

Page 71 - Installation Manual 71

System Set-UpInstallation Manual 73ENGLISHSummaryNote: Some contents may not be displayed depending on DIP switch setting in the main PCB assembly 1.

Page 72 - Installer Setting

System Set-Up 74 Air-to-Water Heat PumpCommon Setting• 3 Minutes DelayFactory use only.• Remote sensor activeIf user connects remote air sensor to c

Page 73 - Installation Manual 73

System Set-UpInstallation Manual 75ENGLISHTemperature range setting• Air cooling set temp.Determine cooling setting temperature range when air tempe

Page 74 - Common Setting

System Set-Up 76 Air-to-Water Heat PumpTemperature Control Parameter Setting • Heater on temperatureUsing Half capacity of electric heater : when DI

Page 75 - Temperature range setting

System Set-UpInstallation Manual 77ENGLISH• Seasonal auto modeWeather dependent mode in heating and cooling, auto change over in heating, cooling and

Page 76 - 76 Air-to-Water Heat Pump

System Set-Up 78 Air-to-Water Heat Pump• Tank disinfection setting 1, 2Disinfection operation is special DHW tank operation mode to kill and to prev

Page 77 - Installation Manual 77

System Set-UpInstallation Manual 79ENGLISH• Tank setting 1, 2Descriptions for each parameters are as following.- Min temp. : temperature gap from Max

Page 78 - 78 Air-to-Water Heat Pump

8 Air-to-Water Heat PumpSafety Precautions • Do not touch refrigerant pipe and water pipe or any internal parts while the unit is operating orimmedi

Page 79 - Installation Manual 79

System Set-Up 80 Air-to-Water Heat Pump• Heater priority- Heater priority : determine electric heater and sanitary tank heater on and off.- Example

Page 80 - 2B.01 2B.012B.02 2B.022B.02

Check Points, Maintenance and TroubleshootingInstallation Manual 81ENGLISH10. Check Points, Maintenance and TroubleshootingIf everything is going wel

Page 81 - Installation Manual 81

Check Points, Maintenance and Troubleshooting82 Air-to-Water Heat PumpTo assure best performance of , it is required to perfo

Page 82 - Maintenance

Check Points, Maintenance and TroubleshootingInstallation Manual 83ENGLISHIf operates not properly or it does not start oper

Page 83 - Troubleshooting

Check Points, Maintenance and Troubleshooting84 Air-to-Water Heat PumpTroubleshooting for Error CodeCodeNo.Description Cause Normal Condition1Problem

Page 84 - 84 Air-to-Water Heat Pump

Check Points, Maintenance and TroubleshootingInstallation Manual 85ENGLISHn Calculate refrigerant concentrationRefrigerant concentration = Total amou

Page 85 - Limiting concentration

86 Air-to-Water Heat Pump1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 86

Page 86 - 86 Air-to-Water Heat Pump

1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 100

Page 87

Installation Manual 9ENGLISHSafety PrecautionsCAUTIONInstallation• Always check for gas (refrigerant) leakage after installation or repair of unit.-

Comments to this Manuals

No comments