LG ARNU423NKA4.AMBBLUS User Manual

Browse online or download User Manual for Heat pumps LG ARNU423NKA4.AMBBLUS. LG ARNU123NJA4.AMBBLUS Owner's manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Vertical Air Handling Unit
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
INSTALLATION MANUAL
AIR
CONDITIONER
P/NO : MFL65003108
http://www.lghvac.com
www.lg.com
Copyright © 2014 - 2017 LG Electronics Inc. All Rights Reserved.
ENGLISH FRANÇAIS
ESPAÑOL
1,MFL65003108,영영 2017. 9. 11. 영영 4:59 Page 1
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - CONDITIONER

Vertical Air Handling UnitPlease read this installation manual completely before installing the product.Installation work must be performed in accorda

Page 2 - IMPORTANT!

10 Vertical Air Handling Unit• Position unit for plenum installation.• The plenum should be secured in order to support the installation of adapter ca

Page 3 - TABLE OF CONTENTS

Installation Manual 11ENGLISHInstallationDuct work• Over 10 screws should be used for joining supply duct with the unit.• To prevent vibration transm

Page 4 - Features

12 Vertical Air Handling Unit• It is particular that the units should not be installed in such a manner that the access panels facing upor down• It sh

Page 5 - Duct Connection Dimensions

Installation Manual 13ENGLISHInstallationPreparation of PipingCut the pipes1. Use the pipes purchased locally.2. Measure the distance between the ind

Page 6 - Safety Precautions

14 Vertical Air Handling UnitNote: Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bindthem together wit

Page 7 - Installation Manual 7

Installation Manual 15ENGLISHInstallation3214561 Refrigerant piping 4 Taping2 Pipe to be brazed 5 Valve3 Nitrogen 6 Pressure-reducing valveAlways blo

Page 8 - 8 Vertical Air Handling Unit

16 Vertical Air Handling UnitInstallationNitrogen substitution methodWelding, as when heating without nitrogen substitution a large amount of the oxid

Page 9 - Installation

Installation Manual 17ENGLISHInstallationRecommendInsulationInsulate the joint and tubes completely.Thermal insullaton : All thermal insulation must

Page 10 - Upflow Installation

18 Vertical Air Handling UnitInstallation• The drainage performance has to be optimized by installing both primary and secondary drain linesalong with

Page 11 - Duct work

Installation Manual 19ENGLISHInstallationMore than 2 inch(51mm)Drainage holeU-TrapBCA ≥ 2-9/16 inch (70mm) B ≥ 2CC ≥ 2 x SPSP = External Pressur

Page 12 - Horizontal-left Installation

2 Vertical Air Handling UnitIMPORTANT!CAUTION: Improper installation, adjustment, alteration, service or maintenance can void the warranty.The weight

Page 13 - Preparation of Piping

20 Vertical Air Handling UnitInstallationConnect the wires to the terminals on the control board individually according to the outdoor unitconnection.

Page 14

Installation Manual 21ENGLISHInstallationAfter the confirmation of the above conditions, prepare the wiring as follows:1) Never fail to have individu

Page 15 - Moisture

22 Vertical Air Handling UnitInstallationCAUTION :The connecting cable connected to the indoor and outdoor unit should be complied with the fol-lowing

Page 16 - ◆How to work

Installation Manual 23InstallationENGLISHElectric HeaterTerminal BlockHeater CableRelayHeater CoilBracketBi metal※ If you want to know more optional

Page 17 - Recommend

24 Vertical Air Handling UnitInstallationDip Switch SettingFor Multi V Models, DIP switch 1, 2, 6, 8 must be set OFF.CAUTIONFunction Description Setti

Page 18 - Condensate Drain

Installation Manual 25ENGLISHInstallationGroup Control SettingMasterGNDSignal12 VLGAP Network SystemMaster Slave Slave SlaveDisplay Error MessageOnly

Page 19 - Applied U-Trap Dimension

26 Vertical Air Handling UnitInstallationGNDSignal12 VLGAP Network SystemMaster Master Slave SlaveDonʼt connect serial 12V lineorDisplay Error Message

Page 20 - Wiring Connection

Installation Manual 27ENGLISHInstallationGNDSignal12 VLGAP Network SystemMNMasterSlaveDisplay Error MessageMasterFAUSlaveFAUMasterorMaster MasterDisp

Page 21 - HAND OVER

28 Vertical Air Handling UnitInstallationLGAP Network SystemMasterSlaveGNDSignal12 VorDisplay Error MessageMasterSlaveSlaveSlave4. 2 Remote Controln W

Page 22 - Power wire(Ground wire)

Installation Manual 29ENGLISHInstallationThe A-weighted sound pressure emitted by this product is below 70 dB.** The noise level can vary depending o

Page 23 - Electric Heater

Installation Manual 3ENGLISHVertical Air Handling Unit Installation ManualTABLE OF CONTENTSo Four type "A" screwso Pipes: Gas sideLiquid si

Page 24 - DIP switch 7 segment

30 Vertical Air Handling UnitProduct DataExternal Static Pressure & Air FlowProduct DataAir handler units are UL Listed up to 0.5 in.wc external s

Page 25 - 1. Group Control 1

Installation Manual 31ENGLISHHeater Capacity(kW) Static pressure drop (in.wc)0 05 – 0.0110 – 0.0215 – 0.0420 – 0.06Electric Heater Static pressure dr

Page 26 - 2. Group Control 2

32 Vertical Air Handling UnitProduct DataAir Filter (Field supply) Static pressure drop factorsIf the air filter has been installed, then the ESP val

Page 27 - 3. Group Control 3

US1. Please call the installing contractor of your product, as warranty service will be provided by them.2. If you have service issues that have not b

Page 28 - 4. 2 Remote Control

Wiring knockouts for conduit Wiring knockouts for conduit Refrigerant connectionsDrain connections for horizontal applicationFilter accessDrain connec

Page 29 - ARN U 336 ANJ 4

ENGLISHFeatureInstallation Manual 5Duct Connection Dimensions<Top> <Front> <Bottom> <Side-right> Refrigerant connections Drai

Page 30 - Product Data

Safety Precautions6 Vertical Air Handling UnitSafety PrecautionsTo prevent injury to the user or other people and property damage, the following instr

Page 31 - (Unit : CFM)

Safety PrecautionsENGLISHInstallation Manual 7Do not allow water to run intoelectric parts.• It may cause There is risk of fire,failure of the produ

Page 32 - 32 Vertical Air Handling Unit

8 Vertical Air Handling UnitSafety PrecautionsCAUTIONn InstallationAlways check for gas (refrigerant) leakageafter installation or repair of product.•

Page 33

Installation Manual 9ENGLISHInstallation• Where optimum air distribution can be ensured.• Where nothing blocks air passage and install the duct work.

Comments to this Manuals

No comments