P/NO : MFL40910604
INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
www.lg.com
ENGLISH
ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
Page view 0
1 2 ... 43

Summary of Contents

Page 1 - AIR CONDITIONER

P/NO : MFL40910604INSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation wo

Page 2 - TABLE OF CONTENTS

10 Air ConditionerWall5~7mmIndoor OutdoorSet screw ofpaper model (4 pieces)Paper modelfor installationCeiling board150mmAdjust the same heightCeiling

Page 3 - Safety Precautions

The Indoor Unit Installation Installation Manual 11ENGLISH2. Duct typeDrainage holeM10 NutM10 SP. washer M10 washer X 4X 4(Localsupply)X 4M10 NutM10

Page 4 - 4 Air Conditioner

12 Air ConditionerThe Indoor Unit Installation 1 Set anchorOld building New building2 Plate washer3 Spring washer4 Nut5 Suspension boltsCAUTION:Ti

Page 5 - ■ Operation

The Indoor Unit Installation Installation Manual 13ENGLISHCeilingCAUTION1~3mmDrainage holeDrainage holeU-TrapBCA 70mmB 2CC 2 x SPSP = Exter

Page 6 - Duct type

14 Air ConditionerThe Indoor Unit Installation 3. Convertible typeOpen side cover1. Remove two screws from side-cover asshown in fig.2. Unlock side-

Page 7 - 2. Outdoor unit

The Indoor Unit Installation Installation Manual 15ENGLISHMOUNTING THE ANCHOR NUT ANDBOLT• Prepare 4 suspension bolts. (Each bolts lengthshould be s

Page 8 - 8 Air Conditioner

16 Air ConditionerThe Indoor Unit Installation Hang the Indoor unit on suspension bolt as per following guidelines:1. Lift the indoor unit to suf

Page 9 - The indoor unit installation

The Indoor Unit Installation Installation Manual 17ENGLISH1) Indoor unit installation Before Installing, prepare Installation Plates• 'Installa

Page 10 - Indoor Outdoor

18 Air ConditionerThe Indoor Unit Installation • Insert the nuts and washer onto thesuspension bolts for locking the suspensionbolts on the ceili

Page 11 - 2. Duct type

The Indoor Unit Installation Installation Manual 19ENGLISHDrain hoseCeilingCeilingCAUTIONCeiling1. Install declination of the indoor unit is very im

Page 12 - Tighten the nut and bolt top

2 Air ConditionerAir Conditioner Installation ManualTABLE OF CONTENTSSafety Precautions ...3Installation of Indoor,Outdoor unit...6The

Page 13 - UNIT AND DRAIN PIPING

20 Air ConditionerThe Indoor Unit Installation • Secure the unit to the Installation Plateswith four M8 bolts and washers.• Hook up the Inlet Gri

Page 14 - Edge part

The Indoor Unit Installation Installation Manual 21ENGLISH2) Installation on the Wall• Select and mark the position for fixing boltsand piping hole.

Page 15 - MOUNTING THE ANCHOR NUT AND

Install the Indoor unit onto Installation Plate.• Insert 2 hooks on the both left and rightside of the unit to the inner slot (wall side)of the Instal

Page 16 - Indoor unit installation

The Indoor Unit Installation Installation Manual 23ENGLISH3) Installation on the floorInstallation of Mount Bracket.• Select and mark the position f

Page 17 - 1) Indoor unit installation

24 Air ConditionerRemote Controller Preparation (Convertible type)Remote control box bodyCord clamp(accessory)Lever carefully the box open using a scr

Page 18 - 18 Air Conditioner

Installation Manual 25ENGLISHWiring Connection• Open the control box cover and connect the Remote controller cord and Indoor power wires.[Air inlet s

Page 19 - Drain hose

26 Air ConditionerElectrical WiringConnecting the cable to Outdoor UnitWiring Connection1. All wiring must comply with LOCAL REGULATIONS.2. Select a p

Page 20 - Cabinet Bottom

Installation Manual 27ENGLISHConnecting Pipes to the Indoor UnitMain cause of gas leakage is defect in flaringwork. Carry out correct flaring work in

Page 21

28 Air ConditionerConnecting Pipes to the Indoor Unit1. Form the piping according to its routing.Avoid bending and bending back the samepiping point m

Page 22 - Inner slot

Installation Manual 29ENGLISHInstallation to Decorative Panel1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit bod

Page 23 - Floor mount

Safety PrecautionsInstallation Manual 3ENGLISHTo prevent the injury of the user or other people and property damage, the following instructionsmust b

Page 24 - ELECTRICAL WIRING

30 Air ConditionerIndoor Unit Drain Piping CAUTION:Install certainly the decorative panel.Cool air leakage causes sweating.Water drops fall.• Drain

Page 25 - Wiring Connection

Installation Manual 31ENGLISHIndoor Unit Drain Piping2. Duct type1) Remove the Air Filter.2) Check the drainage.• Spray one or two glasses of water u

Page 26 - Electrical Wiring

32 Air ConditionerIndoor Unit Drain Piping3. Convertible type1. Set the air direction louvers up-and-down tothe position(horizontally) by hand.To chec

Page 27 - Preparation of Piping

Installation Manual 33ENGLISHIndoor Unit Drain Piping1. Use the heat insulation material for the refrigerant piping which has an excellent heat-resis

Page 28 - Vacuum drying

34 Air ConditionerIndoor Unit Drain Piping In cases where the Outdoor unit isinstalled above the Indoor unitperform the following.1. Tape the piping

Page 29 - Piping side

Installation Manual 35ENGLISHTest running 1. PRECAUTIONS IN TEST RUNNING• The initial power supply must provide at least 90% of the rated voltage.Ot

Page 30 - Indoor Unit Drain Piping

36 Air ConditionerCAUTION: After the confirmation of the above conditions, prepare the wiringas follows:1) Never fail to have an individual power spec

Page 31 - Drain test

Installation Manual 37ENGLISH1. Two Thermistor System(1) Open the rear cover of the wired remote-controller to set the mode.(2) Select one of three s

Page 32 - 32 Air Conditioner

38 Air Conditioner2. Adjusting air volume to the height of ceiling (Cassette type)You can choose the RPM(or air volume) of indoor motor according to t

Page 33 - Forming the piping

Installation Manual 39ENGLISH(1) Open the rear cover of the wired remote-controller to set the mode.(2) Select one of three selectable modes as follo

Page 34 - Settlement of outdoor unit

4 Air ConditionerSafety PrecautionsDo not install the product at a place that thereis concern of falling down.• Otherwise, it may result in personal i

Page 35 - Test running

40 Air ConditionerOptional Operation4. How to Set E.S.P?PreheatZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterHumidifyOut doorT

Page 36 - HAND OVER

Installation Manual 41ENGLISHOptional Operation[Table. 1]Note: 1. Be sure to set the value refering table 1. Unexpected set value will cause mal-func

Page 37 - Optional Operation

42 Air ConditionerOptional Operation1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkalinegas, are produ

Page 39

Installation Manual 5ENGLISHSafety Precautions InstallationInstall the drain hose to ensure that draincan be securely done.• Otherwise, it may cau

Page 40 - Procedure of RPM change:

6 Air ConditionerInstallation of Indoor, Outdoor UnitInstallation of Indoor, Outdoor Unit1. Indoor unitCassette type• There should not be any heat sou

Page 41

Installation of Indoor, Outdoor Unit Installation Manual 7ENGLISHConvertible type• Do not have any heat or steam near the unit.• Select a place wher

Page 42 - 42 Air Conditioner

8 Air ConditionerInstallation of Indoor, Outdoor Unit 3. Piping length and the elevationGas Liquid Standard Max. Standard Max.24k Btu/h5/8"(15.

Page 43

Installation Manual 9ENGLISHThe indoor unit installationThe indoor unit installation1. Cassette typeLevel gaugeCeilingUnit:mm570 Unit size570 Unit si