Ownerʼs & Installation Manual 13
ENGLISH
TEMP
FAN
SPEED
OPER
MODE
When pressing the button and
button simultaneously for more than 3
seconds, the system will be entered into
the installer setting mode.
- After entering into the installer setting
mode, select the ceiling height setting
code value by pressing the button.
* Ceiling height setting code value : 05
1
Select the desired setting value with the
temperature up(), down() button.
2
When pressing the button, currently
established ceiling height value will be
set up.
3
When pressing the button and
button simultaneously for more than 3
seconds after the setting has been
completed, the setting mode will be released.
- If there isn’t any button input for more
than 25 seconds, the installer setting
mode will also be released.
4
OPER
MODE
OPER
MODE
Code value
*Setting value
01: Low
02: Standard
03: High
04: Very high
OPER
MODE
Value
Installation instruction
Installer Setting -Ceiling Height Selection
This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product)
Ceiling height setting is available only for some products.
Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit.
Refer to the product manual for more details.
Ceiling Height Level Description
01 Low Decrease the indoor airflow rate 1 step from standard level
02 Standard Set the indoor airflow rate as standard level
03 High Increase indoor airflow rate 1 step from standard level
04 Very high Increase indoor airflow rate 2 steps from standard level
<Ceiling Height Selection Table>