LG MU3M21.UE0R0 User Manual

Browse online or download User Manual for Unknown LG MU3M21.UE0R0. LG MU3M21.UE0R0 Owner's manual [bs] [hr]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 37
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
P/NO : 3828A20567T
www.lg.com
INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : MULTI
ENGLISH ITALIANO
ESPAÑOL FRANÇAIS DEUTSCH
Page view 0
1 2 ... 37

Summary of Contents

Page 1 - AIR CONDITIONER

P/NO : 3828A20567Twww.lg.comINSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Insta

Page 2 - CONTENTS

10 Multi Air ConditionerInstallation of Indoor, Outdoor UnitPreparing work for Installation (ART COOL Type Only)Open panel front1. First, push the fro

Page 3 - Standard Type

Installation Manual 11ENGLISHInstallation of Indoor, Outdoor Unit• Drill the piping hole with a Ø65mm holecore drill. Drill the piping hole at either

Page 4 - Safety Precautions

12 Multi Air ConditionerFlaring Work and Connection of PipingFlaring workMain cause for gas leakage is due to defect in flaring work. Carry out correc

Page 5 - Installation Manual 5

Installation Manual 13ENGLISHFlaring Work and Connection of PipingInstall the remote control box and cord correctly.• Although the room temperature s

Page 6 - Select the best location

14 Multi Air ConditionerFlaring Work and Connection of Piping• Since the room temperature sensor is in the remote controller, the remote controller bo

Page 7 - Fixing Installation Plate

Flaring Work and Connection of Piping Installation Manual 15ENGLISHCheck1. Compare the flared work with figure below.2. If flare is noted to be def

Page 8 - Piping length and elevation

16 Multi Air ConditionerFlaring Work and Connection of PipingIndoor unit installation1. Hook the indoor unit onto the upper portion ofthe installation

Page 9 - Refrigerant charge

Flaring Work and Connection of Piping Installation Manual 17ENGLISH3. Bundle the piping and drain hose together bywrapping them with vinyl tape ove

Page 10 - Drain hose junction

18 Multi Air ConditionerFlaring Work and Connection of Piping• For the units with capacity more than 48 kBtu/h,the installation piping is connectable

Page 11 - Drill a hole in the wall

Flaring Work and Connection of Piping Installation Manual 19ENGLISHFacing upwardsViewed from point Ain direction of arrowHorizontalplaneGas PipeMod

Page 12 - Point down

2 Multi Air ConditionerMulti Type Air Conditioner Installation ManualCONTENTSInstallation Parts Provided...3Safe

Page 13 - The lower part

20 Multi Air ConditionerFlaring Work and Connection of PipingInstallation• This unit may be installed suspended from the ceiling or mounted on the wal

Page 14 - (1.5meters)

Flaring Work and Connection of Piping Installation Manual 21ENGLISH: • This unit has two different installation types:(1) Ceiling-suspended type

Page 15 - Connection of piping - Indoor

22 Multi Air ConditionerConnecting the Cable between Indoor Unit and Outdoor UnitConnecting the Cable between Indoor Unit and Outdoor UnitConnect the

Page 16 - Indoor unit installation

Connecting the Cable between Indoor Unit and Outdoor UnitInstallation Manual 23ENGLISHConnect the cable to the Outdoor unit.1. Remove the cover contr

Page 17 - Vinyl tape(wide)

24 Multi Air ConditionerConnecting the Cable between Indoor Unit and Outdoor Unit(1) Remove the control cover. Loosen the twoscrews, and slide the cov

Page 18 - Torque wrench

Checking the Drainage, Forming the Pipings and Long Pipe SettingInstallation Manual 25ENGLISHChecking the Drainage, Forming the Pipings and Long Pipe

Page 19 - Installation Manual 19

26 Multi Air ConditionerChecking the Drainage, Forming the Pipings and Long Pipe SettingForming the pipingForm the piping by wrapping theconnecting po

Page 20 - Installation

Checking the Drainage, Forming the Pipings and Long Pipe Setting Installation Manual 27ENGLISHLong Pipe Setting1. Open the top cover of outdoor uni

Page 21 - Installation of The Main Unit

28 Multi Air ConditionerAir Purging and EvacuationAir Purging and EvacuationAir and moisture remaining in the refrigerant system have undesirable effe

Page 22 - Use a circuit breaker

Air Purging and EvacuationInstallation Manual 29ENGLISH1. Connect the charge hose end described in thepreceding steps to the vacuum pump toevacuate t

Page 23 - Outdoor unit

Installation Parts Provided Installation Manual 3ENGLISHInstallation Parts Provided Installation plateType "B" screwsType "A"

Page 24 - In Case of 3 rooms

30 Multi Air ConditionerPanel Front Assembly Panel Front Assembly (ART COOL type Only)1. First, Check the side coverassembly exactly, Fix power cord

Page 25 - Drain piping

Installation PI485 Installation Manual 31ENGLISHInstallation PI485• Fix the PI485 PCB as shown in Fig.Detailed installation method refer to PI485 I

Page 26 - 26 Multi Air Conditioner

32 Multi Air ConditionerInstallation PI485 27kBtu/h30kBtu/h1Ø : 40kBtu/h, 48kBtu/h, 56kBtu/h3Ø : 42kBtu/h, 48kBtu/h, 54kBtu/h

Page 27 - Installation Manual 27

Installation Manual 33ENGLISHTest Running Test Running1. Check that all tubing and wiring have been properly connected.2. Check that the gas and li

Page 28 - Air Purging and Evacuation

34 Multi Air ConditionerMax Combination Capacity Max Combination CapacityMulti Piping Type14 2 5,7,9,12 2216 2 5,7,9,12 2418 3 5,7,9,12,18 3021 3 5,

Page 29 - Evacuation

Installation Manual 35ENGLISHInstallation guide at the seasideInstallation guide at the seasideSeasonal wind and cautions in winter1. Air conditioner

Page 30 - Connector

36 Multi Air Conditioner

Page 32 - 30kBtu/h

4 Multi Air ConditionerDo not disassemble or repair the product. • Contact your dealer or service center.Always earth the product.• It will cause fire

Page 33 - Test Running

Installation Manual 5ENGLISHSafety Precautions Do not put the heater, etc. near the powercable.• Otherwise, it may cause fire and electric shock.Co

Page 34 - Max Combination Capacity

6 Multi Air ConditionerInstallation of Indoor, Outdoor UnitInstallation of Indoor, Outdoor UnitRead completely, then follow step by step.Indoor unit1.

Page 35 - Sea wind Sea wind

Installation of Indoor, Outdoor Unit Installation Manual 7ENGLISHThe wall you select should be strong andsolid enough to prevent vibration1. Mount

Page 36 - 36 Multi Air Conditioner

Installation of Indoor, Outdoor Unit8 Multi Air Conditionerh2h1h1AABranch PipeMain PipeDistributorDistributorBBh2Multi Piping Type Distributor TypeMul

Page 37

Installation of Indoor, Outdoor Unit Installation Manual 9ENGLISH14/16 7.5 20 30 2018 7.5 25 40 2021 7.5 25 70 2024/27 7.5 25 70 2030 7.5 25 75

Comments to this Manuals