ENGLISH
Installation Manual 79
System Set-Up
22
Function
Description
Value #1
Note
-
-
-
-
Default 16°C
Range 16~25°C
Value #2
Note
Default 00
Range
23
Function
Description
Function
Description
Value #1
Note
Default -10°C
Range -20~05°C
Value #2
Note
Default 15°C
Range 10~20°C
24
Value #1
Note
Default 21°C
Range 20~30°C
Value #2
Note
Default 16°C
Range 16~19°C
25
Function
Description
Value #1
Note
Default 55°C
Range 35~55°C
Value #2
Note
Default 15°C ( * 20°C)
Range 15~34°C ( * 20~34°C)
26
Function
Description
Value #1
Note
Default 00
Range 00~01
Sanitary water
heating should be
* : Electric heater is
not used.
enable
• If sanitary water
heating is disable,
Code Item
Setting Cut-off Temperature in Cooling Mode
(FCU setting included)
Determine leaving water temperature when the product is turned off.
This function is used for preventing condensation
on the floor in cooling mode.
Cut-off temperature. Value #1 is valid when Value #2 is
'01 (that means, FCU is installed)'."
Determines if FCU is installed or not. '01' means 'FCU is
NOT installed', and '00' means 'FCU is installed.'
00(Equipped)~01(NOT Equipped)
Setting outdoor temperature range for Weather-dependent
operation
Setting outdoor Max/Min temperature for weather-dependent
operation
Upper Limit of setting range
Lower Limit of setting range
Setting indoor air temperature range for Weather-dependent
operation
Setting indoor Max/Min temperature for weather-dependent
operation
Upper Limit of setting range
Lower Limit of setting range
Setting leaving water temperature range for Weather-dependent operation
Setting leaving water Max/Min temperature for
weather-dependent operation
Upper Limit of setting range
Lower Limit of setting range
Setting Disinfection Operation
Setting start/maintain time for disinfection
Enable/Disable of Disinfection Operation(00:Disable , 01:Enable)
Detail Remark