Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Air-to-Water Heat Pump
Original instruction
[
Representative
] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu,
Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
INSTALLATION MANUAL
AIR
CONDITIONER
P/NO : MFL68681804
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Page view 0
1 2 ... 97

Summary of Contents

Page 1 - CONDITIONER

www.lg.comPlease read this installation manual completely before installing the product.Installation work must be performed in accordance with the nat

Page 2 - TABLE OF CONTENTS

10 Air-to-Water Heat PumpSafety Precautions For installation, alwayscontact the dealer or anAuthorized ServiceCenter.• There is risk of fire,electri

Page 3 -

Installation Manual 11ENGLISHSafety Precautionsn InstallationAlways check for gas(refrigerant) leakageafter installation orrepair of unit.• Low refri

Page 4 - 4 Air-to-Water Heat Pump

12 Air-to-Water Heat Pump2. Installation PartThank you for choosing LG Electronics Air-to-Water Heat Pump Before starting installation, please make i

Page 5 - Installation Manual 5

Installation Manual 13ENGLISHGeneral Information3. General InformationModel InformationWith advanced inverter technology, is s

Page 6 - 1. Safety Precautions

14 Air-to-Water Heat PumpGeneral Information*1 : tested under Eurovent Heating condition (water temperature 30°C ’ 35°C at outdoor ambient temperature

Page 7 - Installation Manual 7

General InformationInstallation Manual 15ENGLISHIf is installed with pre-existing boiler, the boiler and should not beoperated together. If enterin

Page 8 - 8 Air-to-Water Heat Pump

CASE 2: Connecting Sanitary Water TankOutdoor IndoorOutdoor UnitIndoor UnitFloor heating loopFan coil unit SanitarywatertankHot waterCity waterRadiato

Page 9 - Installation Manual 9

General Information CASE 3: Connecting Solar thermal systemSolar heat sourceOutdoor IndoorOutdoor UnitIndoor UnitFloor heating loopFan coil unit San

Page 10 - Safety Precautions

18 Air-to-Water Heat PumpCycle DiagramDescriptionINDOOR UNIT OUTDOOR UNITIndoor UnitPlate HeatExchanger(Accessories)Outdoor UnitEEVHeat ExchangerCOMPR

Page 11 - Installation Manual 11

General InformationWater cycleSanitary water tank is installed (Sanitary water tank kit is necessary) Solar thermal system is connected (Solar therma

Page 12 - 2. Installation Part

Air-to-Water Heat Pump Installation ManualTABLE OF CONTENTSPREFACE...

Page 13 - 3. General Information

General Information Description- Meaning is expressed based on Coolingmode.- TH3, TH4, and TH5 are connected at 6 pintype connector CN_TH3.- Heating

Page 14 - General Information

General InformationParts and DimensionsIndoor unit(External)315490850315.3474DescriptionNo Name Remarks1 Door Control panel is shown after this door i

Page 15 - Typical Installation Example

General Information DescriptionIndoor unit(Internal)474848305663975.1100817610952474No Name Remarks1 Refrigerant Pipe Ø15.88mm(5~16kW), Ø12.7mm (3kW

Page 16 - CASE 2:

General InformationOutdoor unit(External)Supporter490DescriptionNo Name123Liquid-side Service ValveGas-side Service ValveAir discharge GrillProduct He

Page 17 - • Sanitary water tank

DescriptionNo Name123Liquid-side Service ValveGas-side Service ValveAir discharge GrillGeneral Information Product HeatingCapacity : 3kWUE Chasis(un

Page 18 - Cycle Diagram

General InformationSupporterDescriptionNo Name123Liquid-side Service ValveGas-side Service ValveAir discharge GrillProduct HeatingCapacity : 5kW,7kW,9

Page 19 - Water cycle

General Information Control PartsControl Box : Indoor Unit67 78561089815 43 21DescriptionNo Name Remarks12345678910Terminal blocksUnit ELBWater tank

Page 20 - Description

General InformationControl Panel1023414WATERWATERTEMPTEMPOPEROPERHEATINGHEATINGMODEMODEڸۀڿھڽہڹںڻڼۂۃۄWiring Diagram : Indoor Unit- Refer to the wiring

Page 21 - No Name Remarks

General Information Wiring Diagram : Indoor and Outdoor Unit(Including Field wiring)(Indoor : Electric Heater 1Ø, Outdoor : 1Ø)28 Air-to-Water Heat

Page 22 - Indoor unit(Internal)

General InformationWiring Diagram : Indoor and Outdoor Unit(Including Field wiring)(Indoor : Electric Heater 3Ø 380-415V, Outdoor : 3Ø)Installation Ma

Page 23 - Outdoor unit(External)

MOUNTING TO WALL ...33 WATER

Page 24 - (unit:mm)

Installation of Outdoor Unit 4. Installation of Outdoor UnitThe outdoor unit of is installed outside to exchange heat with a

Page 25 - U4 Chassis

Installation of Outdoor UnitInstallation at SeasideSeasonal wind and cautions in winter1. Air conditioners should not be installed in areas where corr

Page 26 - Control Parts

Installation of Indoor Unit 5. Installation of Indoor UnitThe indoor unit of is installed inside where terminal of under floo

Page 27 - Wiring Diagram : Outdoor Unit

Installation of Indoor UnitMounting to WallStep 1. After releasing eight screws, detach front cover from the indoor unit. While detaching thefront co

Page 28 - 28 Air-to-Water Heat Pump

Installation of Indoor Unit 34 Air-to-Water Heat PumpWater volume and pump capacityThe water pump is three speed-adjustable (Maximum / Medium / Mini

Page 29 - Installation Manual 29

Installation Manual 35ENGLISHAHNW16606A2, AHNW16809A2Pump model : UPML 25-95 130 AUTOSelecting a water flowrate outside the curves can cause damage t

Page 30 - Indoor Outdoor

36 Air-to-Water Heat PumpInstallation of Indoor Unit Pressure DropWhen installing the product, install additional pump in consideration of the press

Page 31 - Installation at Seaside

Installation of Indoor UnitWater Volume and Expansion Vessel PressureInside expansion vessel is included which is 8 liter capac

Page 32 - Service Space

Installation of Indoor Unit Water QualityWater quality should be complied with EN 98/83 EC Directives. Requirement for resolved chemicalingredients

Page 33 - (Hall marks)

Piping and Wiring for Outdoor Unit6. Piping and Wiring for Outdoor UnitProcedures about refrigerant piping and electric wiring at the outdoor are desc

Page 34 - 34 Air-to-Water Heat Pump

SANITARY WATER TANK AND SANITARY WATER TANK KIT/SOLAR THERMAL KIT...61 GENERAL INFORMATION ...

Page 35 - AHNW16606A2, AHNW16809A2

Piping and Wiring for Outdoor Unit Step 1. Cut the pipes and the cable.• Use the accessory piping kit or the pipespurchased locally.• Measure the di

Page 36 - Pressure Drop

Piping and Wiring for Outdoor UnitConnecting Pipe to Indoor UnitConnecting pipe to the indoor unit is two steps. Read following directions carefully.C

Page 37 - Installation Manual 37

Piping and Wiring for Outdoor Unit Step 2. Tightening• Align the center of the pipes and sufficientlytighten the flare nut by hand.• Tighten the fla

Page 38 - Frost protection

Piping and Wiring for Outdoor UnitConnecting Pipe to Outdoor Unit(Product Heating Capacity : 9kW)• Align the center of the pipings and sufficientlytig

Page 39 - Refrigerant Piping

Piping and Wiring for Outdoor Unit Two kind of cables should be connected to the outdoor unit : One is ‘Power cable’, the other one is ‘Connecting c

Page 40 - Preparation for Piping

Piping and Wiring for Outdoor Unit• European/International Technical Standard setting the limits for voltage changes, voltagefluctuations and flicker

Page 41 - Backward

Piping and Wiring for Outdoor Unit After checking and confirming following conditions, start wiring work.1. Secure dedicated power source for the Ai

Page 42 - Outdoor unit

Piping and Wiring for Outdoor UnitAfter pipes are connected and electric cables are wired, pipe forming and some tests are remained. Especially,carefu

Page 43

Piping and Wiring for Outdoor Unit Air and moisture remaining in the refrigerant system have undesirable effects as indicated below.1. Pressure in t

Page 44 - Power wire

Piping and Wiring for Outdoor UnitEvacuation1. Connect the charge hose end described in thepreceding steps to the vacuum pump to evacuatethe tubing an

Page 45 - Circuit Breaker Specification

PrefaceInstallation Manual 5ENGLISHPrefaceThis installation manual is to present information and guide about understanding, installing, and checking

Page 46 - 46 Air-to-Water Heat Pump

Piping and Wiring for Indoor Unit 7. Piping and Wiring for Indoor UnitProcedures about water piping and electric wiring at the indoor unit are descr

Page 47 - Finalizing

Piping and Wiring for Indoor UnitInstalling shut-off valve • While assembling two shut-off valves, that are found inside ‘AWHP Installation Kit(AET693

Page 48 - Leakage test and Evacuation

Piping and Wiring for Indoor Unit Water ChargingFor water charging, please follow below procedures.Step 1. Open all valves of whole water circuit. S

Page 49 - Evacuation

Piping and Wiring for Indoor UnitGeneral ConsiderationFollowings are should be considered before beginning indoor unit wiring.• Field-supplied electri

Page 50

Piping and Wiring for Indoor Unit Terminal Block Information (1Ø Electric Heater)Symbols used below pictures are as follows :- L, L1, L2 : Live (230

Page 51 - Installation Manual 51

Piping and Wiring for Indoor UnitTerminal Block Information (3Ø Electric Heater)Symbols used below pictures are as follows :- L, L1, L2 : Live (230V A

Page 52 - Pipe Insulation

Piping and Wiring for Indoor Unit Connecting with Outdoor UnitElectric Heater Wiring1(L) 2(N) 3123Terminal block at outdoor unit123Terminal block at

Page 53 - Electrical Wiring

Accessories Installation8. Accessories InstallationInstallation Manual 57ENGLISHAccessories supported by LG ElectronicsAccessories supported by 3rdpa

Page 54 - 54 Air-to-Water Heat Pump

58 Air-to-Water Heat PumpThermostat is generally used to control the product by air temperature. When thermostat isconnected to the product, the produ

Page 55 - Installation Manual 55

Installation Manual 59ENGLISHHow to wire thermostatFollow below procedures Step 1 ~ Step 5.Step 1. Uncover front cover of the unit and open the contr

Page 56 - Electric Heater Wiring

Safety Precautions6 Air-to-Water Heat Pump1. Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instru

Page 57 - 8. Accessories Installation

Accessories Installation 60 Air-to-Water Heat PumpFinal check• DIP switch setting : Set DIP switch No. 8 to ‘ON’. Otherwise, the unit can not recogn

Page 58 - Thermostat

Accessories InstallationInstallation Manual 61ENGLISHTo establish sanitary water circuit, 3way valve and sanitary water tank kit is required. If sola

Page 59 - How to wire thermostat

How to Install Sanitary Water TankFor more detail information about installing sanitary water tank, please refer installation manualprovided with sani

Page 60 - Final check

Accessories InstallationInstallation Manual 63ENGLISHʶʹʸʶʺTerminal Block 3Terminal Block 1ʸʶʶʷʹʺTerminal Block 1Terminal Block 3Relay contactorport n

Page 61

Step 6. Find sanitary water tank sensor. Connect it to ‘CN_TH4’ (Red Connector) of the indoor unitPCB (symbol Ⓐat the picture). The sensor wire shoul

Page 62 - (unit : mm)

Accessories InstallationInstallation Manual 65ENGLISHHow to Wire Sanitary Water Tank HeaterStep 1. Uncover heater cover of the sanitary water tank. I

Page 63

How to Install Solar Thermal KitStep 1. Check the diameter of pre-installed pipes. (symbol Ⓐ and Ⓑ)Step 2. If the diameter of pre-installed pipes is d

Page 64 - Sanitary Water

Accessories InstallationInstallation Manual 67ENGLISHFinal Check• Flow direction : - Water should flow from water outlet of the indoor unit to sanita

Page 65

Dew Condensation• Wrong wiring can yield dew condensation on the floor. If radiator isconnected at the under floor water loop, dew condensation can be

Page 66 - Remote Temperature Sensor

Accessories InstallationInstallation Manual 69ENGLISHThermostatConditions if Accessories are InstalledThis section describes conditions about install

Page 67 - 3Way Valve

Safety PrecautionsInstallation Manual 7ENGLISHDo not install the waterpipe system as Openloop type.• It may cause failure ofunit.Use a vacuum pump or

Page 68 - 2Way Valve

70 Air-to-Water Heat PumpSanitary Water Tank and Sanitary Water Tank Kit /Solar Thermal KitInstalling sanitary water tank requires following considera

Page 69 - Remote Air Temperature Sensor

Installation Manual 71ENGLISHInstalling recirculation pumpWhen is used with sanitary water tank, it is STRONGLY recommended

Page 70 - Solar Thermal Kit

72 Air-to-Water Heat Pump2Way(3way) Valve2Way(3way) valve should be located between the indoor unit and the water tank.• If enough space is not secure

Page 71 - Water Out

Installation Manual 73ENGLISH9. System Set-UpAs is designed to satisfy various installation environment, it is important to set upsystem correctly.

Page 72 - 2Way(3way) Valve

DIP Switch InformationRole when centralcontroller is equipped11As MasterAs SlaveDescription Setting DefaultAccessory installationinformation23Indoor u

Page 73 - 9. System Set-Up

System Set-UpInstallation Manual 75ENGLISHEmergency Operation• Definition of terms- Trouble : a problem which can stop system operation, and can be r

Page 74 - DIP Switch Information

System Set-Up 76 Air-to-Water Heat Pump• Following features are permitted in emergency operation. :- Operation On/Off- VIEW T

Page 75 - Installation Manual 75

System Set-UpInstallation Manual 77ENGLISHInstaller SettingHow to enter installer setting modeInstaller setting mode is to set the detail function of

Page 76 - 76 Air-to-Water Heat Pump

SummaryExample of Fuction Code DisplayFunction Code Value #1 Value #2Code Item Detail Remark01 Function Additional refrigerant chargingDescription Ins

Page 77 - Installer Setting

System Set-UpInstallation Manual 79ENGLISHCode Item Detail Remark05 Function Setting temperature selectionDescription Selection for setting temperatu

Page 78

8 Air-to-Water Heat PumpSafety Precautions Take care to ensurethat power cable couldnot be pulled out ordamaged duringoperation.• There is risk of f

Page 79 - Installation Manual 79

Code Item Detail Remark12 Value #2 Note Lower limit of setting range(FCU is not equipped)Default 16 °CRange 16 ~ 18 °C13 Function Setting air temperat

Page 80

System Set-UpInstallation Manual 81ENGLISHkrameRliateDmetIedoCedom gnilooc ni erutarepmet ffo-tuc gnitteSnoitcnuF22(FCU setting included)Description

Page 81 - Installation Manual 81

Code Item Detail RemarkNote Starting date (Sunday:1,Monday:2, ···· ,Saturday:7)Default 06Range 01 ~ 07Value #2Value #1Note Starting time in 24 hours(0

Page 82

System Set-UpInstallation Manual 83ENGLISHCode Item Detail Remark2B2E2F42Function Domestic hot water heating timersDescriptionValue #1 NoteDefaultRan

Page 83 - Installation Manual 83

Common Setting• Function Code 01 : Test RunTest run should be performed when additional refrigerant charging is required. To charge therefrigerant, th

Page 84 - Common Setting

System Set-UpInstallation Manual 85ENGLISHTemperature range setting• Function Code 11 : Setting air temperature in cooling modeDetermine cooling sett

Page 85 - Temperature range setting

System Set-Up 86 Air-to-Water Heat Pump1Keep pressing programming button for 3 seconds to enter settingscreed drying mode. 2Press programming button

Page 86 - Left days

System Set-UpTemperature Control Parameter Setting • Function Code 21 : Setting Electric Heater On/Off temperatureUsing Half capacity of electric heat

Page 87 - Installation Manual 87

System Set-Up • Function Code 23, 24, and 25 : Setting Weather-dependent operationWeather-dependent operation is that the product automatically adju

Page 88 - 88 Air-to-Water Heat Pump

System Set-Up• Function Code 26 and 27 : Setting Disinfection operationDisinfection operation is special sanitary tank operation mode to kill and to p

Page 89 - Installation Manual 89

Installation Manual 9ENGLISHSafety PrecautionsTurn the main power on6 hours ago before theproduct startingoperation.• Otherwise, it may causecompress

Page 90 - 90 Air-to-Water Heat Pump

System Set-Up • Function Code 28 and 29 : Setting control parameter for Sanitary water heating operationDescriptions for each parameters are as foll

Page 91 - 2B.01 2B.012B.02 2B.022B.02

System Set-Up• Function Code 2A : Miscellaneous setting- Value #1 of Function Code 2A : determine electric heater and sanitary tank heater on and off.

Page 92 - 92 Air-to-Water Heat Pump

Check Points, Maintenance and Troubleshooting 10. Check Points, Maintenance and TroubleshootingIf everything is going well until now, it is time to

Page 93 - Test Run

Check Points, Maintenance and TroubleshootingTo assure best performance of , it is required to perform periodical check and m

Page 94 - Troubleshooting

Check Points, Maintenance and Troubleshooting If operates not properly or it does not start operation, please check followi

Page 95 - Installation Manual 95

Check Points, Maintenance and TroubleshootingInstallation Manual 95ENGLISHTroubleshooting for Error CodeCodeNo.Description Cause Normal Condition1Pro

Page 96 - Limiting concentration

96 Air-to-Water Heat Pumpn Calculate refrigerant concentrationRefrigerant concentration = Total amount of replenished refrigerant in refrigerant facil