Many
Manuals
search
Categories
Brands
Home
LG
Unknown
ARUN145BTE4.AWGBLUS
User Manual
LG ARUN145BTE4.AWGBLUS User Manual Page 47
Download
Share
Sharing
Add to my manuals
Print
Page
/
95
Table of contents
BOOKMARKS
Rated
.
/ 5. Based on
customer reviews
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
PIPE CONNECTIONS BETWEEN INDOOR AND OUTDOOR UNIT
47
ENGLISH
- Ensure that the branch pipes are attached vertically.
Header
Slave
Master
Slave
Master
Slave
Master
Slave
Master
Slave
Master
Slave
Master
1st
1st
1st
Main pipe
Distribution
2nd
2nd
3rd
3rd
Main pipe
distribution
Slave
Master
1st
3rd
3rd Main pipe distribution
2nd
Horizontal Distribution
Vertical Distribution
The others
Distribution Method
1
2
...
42
43
44
45
46
47
48
49
50
51
52
...
94
95
AIR CONDITIONER
1
TIPS FOR SAVING ENERGY
2
IMPORTANT SAFETY INSTRUCTIONS
3
Operation
4
Installation
5
TABLE OF CONTENTS
7
INSTALLATION PROCESS
8
OUTDOOR UNITS INFORMATION
9
Model Name : ARUN***DTE4
13
ALTERNATIVE REFRIGERANT R410A
17
SELECT THE BEST LOCATION
18
INSTALLATION SPACE
19
Locking points for
21
Forklift Carrying Guide
21
Forklift Carrying Hole
21
INSTALLATION
22
Foundation for Installation
23
Preparation of Piping
24
Opening shutoff valve
25
Closing shutoff valve
26
Moisture
27
Nitrogen substitution method
28
Gas pipe
29
Service Port
29
Liquid pipe
29
Refrigerant
29
Charging Port
29
OUTDOOR UNIT
30
Liquid pipe Gas pipe
32
Refrigerant piping system
33
Header Method
36
H 110m(361ft)
37
L 200m(656ft)
37
40m(131ft)
37
ODU Capacity
37
Master ≥ Slave1 ≥ Slave2
37
Outdoor unit Connection
41
Indoor Unit Connection
41
The amount of Refrigerant
45
Refrigerant charging
46
Distribution Method
47
Branch pipe Fitting
48
Pinched pipe
49
Horizontal plane
49
Cap pipe
49
Insulator for cap pipe
49
Y branch pipe
50
Leak Test and Vacuum drying
52
Liquid side
53
Gas side
53
Vacuum Mode
54
(3.28ft)
55
ELECTRICAL WIRING
56
Round pressure terminal
57
Power cable
57
Front Panel
58
Field Wiring(3Ø, 208/230V)
61
34 34 34
62
[Indoor Units]
63
(Main Switch)
63
Outdoor unit
64
Field Wiring(3Ø, 460V)
67
Outdoor Unit
68
Automatic Addressing
77
B(D) A(C) BA
80
TEST RUN
81
Night Low Noise Function
83
Overall defrost mode
84
Setting the ODU address
85
Target pressure adjusting
87
Error No. of Compressor
88
Error No
88
Error No. of Unit
88
CAUTION FOR REFRIGERANT LEAK
91
Indoor unit
92
Smallest
92
Sea wind
93
Windbreak
93
Comments to this Manuals
No comments
Publish
Related products and manuals for Unknown LG ARUN145BTE4.AWGBLUS
Unknown LG CT-21S11KE User Manual
(28 pages)
Unknown LG T710BH-S User Manual
(18 pages)
Unknown LG SH2 User Manual
(28 pages)
Unknown LG LWN2262BBG User Manual
(20 pages)
Unknown LG FH2C3WD User Manual
(52 pages)
Unknown LG RT-15LA54 User Manual
(28 pages)
Unknown LG DP132 User Manual
(2 pages)
Unknown LG GR-051SF.ASWPKOO User Manual
(8 pages)
Unknown LG 32LD325C User Manual
(2 pages)
Unknown LG VC42201YHTP User Manual
(37 pages)
Unknown LG DH6630T User Manual
(48 pages)
Unknown LG 32MB17HM-B User Manual
(40 pages)
Unknown LG LS-H126PMC0 User Manual
(20 pages)
Unknown LG CT-20S47S User Manual
(20 pages)
Unknown LG TWC186NBABF User Manual
(48 pages)
Unknown LG L1760TQ-BF User Manual
(23 pages)
Unknown LG ARUN144DTE4.AWGBLUS User Manual
(93 pages)
Unknown LG PQWRCQ0FDB.ENCXUAE User Manual
(25 pages)
Unknown LG MS-2342A User Manual
(25 pages)
Unknown LG MH-1296MA User Manual
(31 pages)
Print document
Print page 47
Comments to this Manuals