10 Room Air Conditioner
Installation of Indoor, Outdoor Unit
Drill the piping hole with a ø70mm hole core drill. Drill the piping hole at either the right or the
left with the hole slightly slanted to the outdoor side.
Drill a hole in the wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
5-7mm
(0.2"~0.3")
Indoor
WALL
Outdoor
Standard / Artcool Deluxe type Artcool type
Sticking the installation guide map and fixing Indoor unit (Artcool Type Only)
Plastic anchors
INSTALLATION GUIDE MAP
1
0
m
m
INSTALLATION GU
IN
S
T
A
IIA
T
IO
N
G
U
ID
E
M
A
P
Put an Installation Guide Map on the desired surface.
Make a hole with diameter of 6mm and depth of
30-35mm when piercing a screw point.
Drive the fore plastic anchors into drilled points.
Hang the hole of product at the upper screws.
(In this time, Remove the map)
(Falling attention)
Check the fixed product with light power.
Adjust level even by level guage and fix to installation
for reference on the well.
Drill the piercing part for connecting pipe as diameter
50mm. (In case of piercing rear surface)
Refer to No. 5 on this page when making a hole in the wall.
First, Drive the two points of the upper parts by screws
(Leave 10mm for hanging product)
Drive the lower parts after facing the hole of product
with plastic anchors, and fix completely the upper
screws.
In case of nothing wrong in the matter, connect the pipe
and the wire. (Installation manual reference)
Horizontality
IN
S
T
A
LL
A
T
IO
N
G
U
ID
E
M
A
P
Plastic anchors
INSTALLATION GUIDE MAP
IN
S
T
A
L
L
A
T
IO
N
G
U
ID
E
M
A
P
Hanger hole
(Rear side of
product)
Page view 9