Installation
Manual
25
Installation
Soap
water
method
1.
Remove
the
caps
from
the
2-way
and
3-way
valves.
2.
Remove
the
service-port
cap
from
the
3-way
valve.
3.
To
open
the
2-way
valve
turn
the
valve
stem
counterclockwise
approximately
90°,
wait
for
about
2~3
sec,
and
close
it.
4.
Apply
a
soap
water
or
a
liquid
neutral
detergent
on
the
indoor
unit
connection
or
outdoor
unit
connections
by
a
soft
brush
to
check
for
leakage
of
the
connecting
points
of
the
piping.
5.
If
bubbles
come
out,
the
pipes
have
leakage
Evacuation
1.
Connect
the
charge
hose
end
described
in
the
preceding
steps
to
the
vacuum
pump
to
evacuate
the
tubing
and
indoor
unit.
Confirm
the
"Lo"
knob
of
the
manifold
valve
is
open.
Then,
run
the
vacuum
pump.
The
operation
time
for
evacuation
varies
with
tubing
length
and
capacity
of
the
pump.
The
following
table
shows
the
time
required
for
evacuation.
2.
When
the
desired
vacuum
is
reached,
close
the
"Lo"
knob
of
the
manifold
valve
and
stop
the
vacuum
pump.
Finishing
the
job
1.
With
a
service
valve
wrench,
turn
the
valve
stem
of
liquid
side
valve
counter-clockwise
to
fully
open
the
valve.
2.
Turn
the
valve
stem
of
gas
side
valve
counter-
clockwise
to
fully
open
the
valve.
3.
Loosen
the
charge
hose
connected
to
the
gas
side
service
port
slightly
to
release
the
pressure,
then
remove
the
hose.
4.
Replace
the
flare
nut
and
its
bonnet
on
the
gas
side
service
port
and
fasten
the
flare
nut
securely
with
an
adjustable
wrench.
This
process
is
very
important
to
prevent
leakage
from
the
system.
5.
Replace
the
valve
caps
at
both
gas
and
liquid
side
service
valves
and
fasten
them
tight.
This
completes
air
purging
with
a
vacuum
pump.
The
air
conditioner
is
now
ready
to
test
run.
Gas
side
Liquid
side
Cap
Hexagonal
wrench
2-way
valve
(Open)
3-way
valve
(Close)
Required
time
for
evacuation
when
30
gal/h
vacuum
pump
is
used
10
min.
or
more
15
min.
or
more
If
tubing
length
is
less
than
10m
(33
ft)
If
tubing
length
is
longer
than
10m
(33
ft)
Indoor
unit
Outdoor
unit
Lo
Hi
Manifold
valve
Vacuum
pump
Pressure
gauge
Open
Close