REMOTE
CONTROL
FUNCTION
Operating
Instructions
1.
ABBREVIATION
Ts
:
Setting
Temperature
Tr
:
Room
Temperature
Ti
:
Indoor
defrost
sensor
temperature
2.
OPERATION
OF
MAIN
BOARD
2.1
COOL
MODE
?
If
Tr
>
Ts
cool
operation
is
activated.
Compressor
and
outdoor
fan
are
turned
on.
Indoor
fan
is
started
at
the
previously
set
speed.
?
If
Tr
≤
Ts-1°C,
cool
operation
is
terminated.
Compressor
and
outdoor
fan
are
turned
off.
Indoor
fan
keeps
running
at
the
set
speed.
?
The
range
of
Ts
is
15~30°C.
?
Indoor
fan
speed
can
be
adjusted
for
low,
medium,
high
and
auto.
2.1.1
Delay
protection
of
compressor
in
normal
operation.
3
minutes
before
it
is
turned
on
or
off
2.1.2
Indoor
de-ice
This
process
is
checked
by
the
indoor
defrost
sensor
(Ti).
After
the
compressor
has
worked
for
45
minutes,
if
Ti
≤
0°C
for
3
minutes
continuously,
compressor
and
outdoor
fan
are
turned
off.
Indoor
fan
keeps
running
at
the
set
speed.
When
Ti
≥
8°C
or
indoor
de-ice
operation
is
on
for
more
than
8
minutes,
system
will
return
to
normal
operation.
2.2
FAN
MODE
?
Indoor
fan
runs
at
the
set
speed
while
compressor
and
outdoor
fan
are
turned
off.
?
Indoor
fan
speed
can
be
adjusted
for
low,
medium
and
high.
The
initial
speed
is
medium.
2.3
HEAT
MODE
(Heat
Pump
model
only)
?
If
Tr
<
Ts,
heat
operation
is
activated.
Compressor
and
outdoor
fan
are
turned
on.
The
indoor
fan
is
started
approximately
10
seconds
later.
?
If
Tr.
≥
Ts
+
1°C,
heat
operation
is
terminated.
Compressor
and
outdoor
fan
are
turned
off.
The
indoor
fan
keeps
running
approximately
100
seconds.
?
The
range
of
Ts
is
15~30°C.
?
Indoor
fan
speed
can
be
adjusted
for
low,
medium,
high
and
auto.
?
Compressor
will
delay
for
3
minutes
before
it
is
turned
on
or
off.
2.3.1
Delay
protection
of
compressor
in
normal
operation
3
minutes
before
it
is
turned
on
or
off.
Comments to this Manuals