A9
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
37. FAN Fault Check (Command: d w)
To set Fan control on/off.
* This function only works in Tile Off mode.
Transmission
[d][w][ ][Set ID][ ][Data][Cr]
Data FF: Data should be always ff in hexadecimal.
Acknowledgement
[w][ ][Set ID][ ][OK/NG][Data][x]
Data 00: Abnormal State
01: Normal State
38. Temperature Value (Command: d n)
To read the inside temperature of the display.
Transmission
[d][n][ ][Set ID][ ][Data][Cr]
Data FF: Data should be always ff in hexadecimal.
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
39. Serial No. Check (Command: f y)
To read the serial numbers.
Transmission
[f][y][ ][Set ID][ ][Data][Cr]
Data FF: Data should be always ff in hexadecimal.
Acknowledgement
[y][ ][Set ID][ ][OK/NG][Data][x]
40. S/W Version (Command: f z)
To read the software version.
Transmission
[f][z][ ][Set ID][ ][Data][Cr]
Data FF: Data should be always ff in hexadecimal.
Acknowledgement
[z][ ][Set ID][ ][OK/NG][Data][x]