LG ARUB200LTE4.EWGBLEU User Manual

Browse online or download User Manual for Heat pumps LG ARUB200LTE4.EWGBLEU. LG ARUB080LTE4.EWGBLEU Owner's manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
P/NO : MFL67221416
INSTALLATION MANUAL
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
Original instruction
For more information, Refer to the CD or LG Web site (www.lg.com).
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ČEŠTINA
ΕΛΛΗΝΙΚΆ
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Page view 0
1 2 3 4 5 6 ... 40 41

Summary of Contents

Page 1 - CONDITIONER

P/NO : MFL67221416INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installatio

Page 2 - IMPORTANT SAFETY INSTRUC

10ENGLISHBurrs removal- Completely remove all burrs from the cut cross section of pipe/tube.- Put the end of the copper tube/pipe to downward directio

Page 3

11ENGLISHRefrigerant piping on three principlesDrying Cleanliness AirtightShould be no moistureinsideNo dust inside.There is no refrigerantleakageItem

Page 4

12ENGLISHType of HR Unit Select an HR unit according to the number of the indoor units to be in-stalled. HR units are classified into 3 types by the n

Page 5 - TABLE OF CONTENTS

13ENGLISHGas pipe Ø15.88 (5/8)Liquid pipe Ø9.52 (3/8)Brazing Type 1234Remove caps onThe brazing part.Liquid pipeLow pressure gas pipeHigh pressure gas

Page 6 - SELECT THE BEST LOCATION

- Pipe connections can be done on the front side or on the side accord-ing to the installation environments.- Be sure to let 0.2kgf/cm2Nitrogen flow i

Page 7 - (servicing space)

15ENGLISHMethod of drawing out pipes on the bottom side- Drawing out common pipe through side panelLiquid pipeLow Pressure Gas pipeHigh PressureGas pi

Page 8 - INSTALLATION SPACE

16ENGLISHRefrigerant pipe diameter from outdoor unit to firstbranch. (A)Y branch, Header and HR unit connection patternUpwardoutdoorunit totalcapacity

Page 9 - INSTALLATION

17ENGLISHOutdoor unit ConnectionIndoor Unit ConnectionIndoor Unit connecting pipe from branch (a,b,c,d,e,f)Indoor Unit capacity[kW(Btu/h)]Liquid pipe[

Page 10 - R=0.4~0.8

18ENGLISHPipe Connection Method/Precautions for Series connections between Outdoor units- Separate Y branch joints are needed for series connections b

Page 11 - Nitrogen substitution method

19ENGLISHhh 0.2mToward indoor unitToward indoor unitOil Trap(Example 3)The amount of RefrigerantThe calculation of the additional charge should take i

Page 12 - 2, 3, 4 Outdoor Units

2ENGLISHTIPS FOR SAVING ENERGYHere are some tips that will help you minimize the power consumptionwhen you use the air conditioner. You can use your a

Page 13 - Sealed Piping

20ENGLISH• Header should be insulated with the insulator in each kit.• Joints between branch and pipe should be sealed with the tape in-cluded in each

Page 14 - INDOOR AND OUTDOOR UNIT

21ENGLISH[unit:mm]Leak testLeak test should be made by pressurizing nitrogen gas to 3.8MPa(38.7kgf/cm2). If the pressure does not drop for 24 hours, t

Page 15 - Refrigerant piping system

22ENGLISHBe sure to give insulation work to refrigerant piping by covering liquidpipe and gas pipe separately with enough thickness heat-resistant pol

Page 16

23ENGLISHABEBIABDC1m1mDFGBGDBHIJAPenetrationsⒶ SleeveⒷ Heat insulating materialⒸ LaggingⒹ Caulking materialⒺ BandⒻ Waterproofing layerⒼ Sleeve with ed

Page 17 - Indoor Unit Connection

24ENGLISHUX3UX2Main PCBNoise FilterExternal PCBTake care of the phase sequence of 3-phase 4-wirepower systemWARNINGThe temperature sensor for outdoor

Page 18 - 2m or longer2m or longer

25ENGLISHNOTE!• The figures are based on assumed length of parallel cabling upto 100m. For length in excess of 100m the figures will have tobe recalcu

Page 19 - Refrigerant charging

26ENGLISHField WiringSingle outdoor unitR S T N Switch Fuse L N Communication Line (2 Wires Cable) Power Line (4 Wires Cable) Communication Line (3 Wi

Page 20 - Y branch pipe

27ENGLISHCAUTIONIt should be wiring power cables or communication cables toavoid interference with the oil level sensor. Otherwise, That oillevel sens

Page 21 - Leak Test and Vacuum drying

28ENGLISHSwitch for setup of HR UnitMain function of SW02M1 Selection of the method for addressing valves of an HR unit(Auto/Manual)4 Setting the Valv

Page 22 - Vacuum Mode

29ENGLISHModels Gas Pipe Liquid pipeARBLB03321I.D9.52I.D12.753.6D.I25.9D.II.D9.52I.D12.7I.D6.35I.D12.733232174I.D25.441339083I.D15.88I.D19.05I.D12.7I.

Page 23 - Penetrations

3- Improper installation may cause the unit totopple and result in injury.• Do not install the product on a defective in-stallation stand.- It may cau

Page 24 - Front Panel

30ENGLISHManual pipe detection1 Enter the central control address into each indoor unit using itswired remote control.2 Turn No.1 of SW02M of HR unit

Page 25

31ENGLISH- Above setup must be done for all HR unit valves.- The valve that is not connected with any indoor unit should be ad-dressed with any other

Page 26 - (Main Switch)

32ENGLISHMode Function Option Value ActionRemarks Content Display1 Content Display2 Content Display3 Content Display4 Implement Display5 InstallationS

Page 27

33ENGLISHGroup recognizing the central controllerNo.0 group (00~0F)No.1 group (10~1F)No.2 group (20~2F)No.3 group (30~3F)No.4 group (40~4F)No.5 group

Page 28 - HR Unit PCB

34ENGLISHCAUTION• Ask an authorized technician to setting a function.• If use a function, first install a Central controller.!CAUTION• Ask an authoriz

Page 29 - Automatic Addressing

35ENGLISHSelf-Diagnosis FunctionError Indicator- This function indicates types of failure in self-diagnosis and occurrence of failure for air conditio

Page 30

36ENGLISHDisplay Title Cause of ErrorOutdoor unit related error3 5 * Low Pressure of Master Outdoor Unit Low Pressure of Master Outdoor Unit3 6 *Maste

Page 31 - 7-SEG SW01M SW03M SW04M

37ENGLISHHR Unit related error2 0 01 Searching pipe Error Failure of automatic addressing of valves2 0 1C + #HRHR unit1 Liqiud sensor error Liquid pip

Page 32 - B(D) A(C)

38ENGLISH- With partition and without opening which serve as passage of air toadjoining roomCalculate refrigerant concentration Total amount of replen

Page 33

39ENGLISH• Product Name : Air conditioner• Model Name :• Additional information : Serial number is refer to the bar code on the product.Product Sales

Page 34

4ENGLISH• Use power cables of sufficient current carry-ing capacity and rating. - Cables that are too small may leak, gener-ate heat, and cause a fi

Page 37 - CAUTION FOR REFRIGERANT LEAK

5ENGLISHTABLE OF CONTENTS2 TIPS FOR SAVING ENERGY2 IMPORTANT SAFETY INSTRUCTIONS6 INSTALLATION PROCESS6 OUTDOOR UNITS INFORMATION6 ALTERNATIVE REFRIGE

Page 38 - Smallest

6ENGLISHINSTALLATION PROCESSOUTDOOR UNITS INFORMATIONALTERNATIVE REFRIGERANT R410AThe refrigerant R410A has the property of higher operating pressure

Page 39 - Product information

7ENGLISHSelect installation location of the HR unit suitable for following condi-tions - Avoid a place where rain may enter since the HR unit is for i

Page 40

8ENGLISHDuring the installation of the unit, consider service, inlet, and outletacquire the minimum space as shown in the figures below.CategoryInstal

Page 41

9ENGLISH• Install at places where it can endure the weight and vibration/noiseof the outdoor unit.• The outdoor unit supports at the bottom shall have

Comments to this Manuals