LG GR-B206GVQA User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 125
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
Note1)
The
abnormality
of
RT-Sensor,
R2-Sensor
Icemaker
Unit,
and
Icemaker-Sensor
is
not
indicated
in
trouble
code
but
it
is
indicated
when
checking
LED
(when
pressing
both
freezer
temperature
control
button
and
refrigerator
temperature
control
button
for
more
than
1
second
at
the
same
time).
RT-Sensor Normal
:
A
LED
on,
Abnormal
:
A
LED
Off.
R2-Sensor
Normal
:
B
LED
on,
Abnormal
:
B
LED
Off.
Icemaker
Unit
Normal
:
C
LED
on,
Abnormal
:
C
LED
Off.
Icemaker
Sensor
Normal
:
D
LED
on,
Abnormal
:
D
LED
Off.
2-16.
Test
Function
1.
The
purpose
of
test
function
is
to
check
function
of
the
PCB
and
product
and
to
search
for
the
failure
part
at
the
failure
status.
2.
Test
button
is
placed
on
the
main
PCB
of
refrigerator
(test
switch),
and
the
test
mode
will
be
finished
after
maximum
2
hours
irrespective
of
test
mode
and
then
is
reset
to
the
normal
status.
3.
Function
adjustment
button
is
not
perceived
during
performance
of
test
mode
but
only
warning
sounds
ring.
4.
In
finishing
test
mode,
always
pull
the
power
cord
out
and
then
plug-in
it
again
for
the
normal
state.
5.
If
nonconforming
contents
such
as
sensor
failure
are
found
during
performance
of
test
mode,
release
the
test
mode
and
display
the
failure
code.
6.
Even
if
pressing
the
test
button
during
failure
code
display,
test
mode
will
not
be
performed.
MICOM
FUNCTION
-37-
The
rest
of
LEDs
are
all
on.
Test
1
Test
2
Normal
Conditions
MODE
HANDLING
CONTENTS
REMARKS
Press
TEST
s/w
once.
Press
TEST
s/w
once
at
TEST1
conditions.
Press
TEST
s/w
once
at
TEST2
conditions.
1.
Compressor
continuously
operates.
2.
Freezer
fan
(high
speed
RPM),
Cooling
fan
continuously
operates.
3.
Defrost
heater
is off.
4.
All
display
LEDs
are
on.
5.
Stepping
motor
damper
is
in
open
conditions.
(baffle
is
open)
1.
Compressor
is
off
2.
Freezer
fan,
Cooling
fan
are
off.
3.
Defrost
heater
is
on.
4.
All
display
LEDs
are
off.
(Freezer
room
"2"
LED
and
Refrigerator
room
"2"
LED
are
only
ON.)
5.
Stepping
motor
damper
is
in
closed.
(baffle
is
closed).
Returns
to
the
initial
conditions.
-
Forced
operate.
-
Freezer
fan
is
off
when
door
is
opened.
-
It
returns
to
normal
conditions
when
the
temperature
of
defrost
sensor
is
above
5°C.
-
Forced
defrost.
Compressor
starts
after
seven
minutes
delay.
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 124 125

Comments to this Manuals

No comments