PCS400R Conguration Options
Network and Communication Setup
This section describes PCS400R communication options for conguration purposes.
* Note: Before you proceed with any additional configuration, the PCS400R software should be installed and config-
ured as described in the setup procedure on pages 18 to 20.
Also note that conguration updates periodically require that you reset the PCS400R. Make sure to reset the unit when directed to do so.
There are two typical options for communicating with the PCS400R:
•  Use an SSH client to communicate with the PCS400R via a command line interface. If necessary, consult the network administrator to obtain the
IP address that has been assigned to/congured for the PCS400R’s Control Port.
•  To establish a direct connection to the PCS400R, connect a PC to the PCS400R using the FTDI TTL-USB cable (P/N TTL-232R-5V-AJ). Plug the USB
end of the cable into an open USB port on your PC. If necessary, install the device driver. Plug the other end of the cable into the Service Port jack
on the PCS400R rear panel.
Using HyperTerminal or an equivalent terminal emulation programme on the PC, congure the serial port as follows:
- Bits per second/baud = 115,200
- Data bits = 8
- Parity = None
- Stop bits = 1
- Flow Control = None
* Note : To avoid configuration errors, make sure the keyboard settings on the terminal emulator assign the backspace character to Ctrl + H
(ASCII 8).
You will need to know the admin” user password in order to log in to the command line interface. The default admin user password is
“Password4Partners” (case-sensitive). If necessary, for example, if the password has been changed from its default value, consult the system
administrator to obtain the current admin user password.
* Note : If you want to connect a PC directly to the PCS400R Control Port using an Ethernet CAT5E cable, in order for communication to be
established, the PCS400R’s IP address must be on the same subnet as the PC’s IP address.