INSTALLATION MANUAL
AIR CONDITIONER
Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national
wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading
it thoroughly.your set and retain it for future reference.
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ČEŠTINA
ΕΛΛΗΝΙΚΆ
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
PORTUGUESE
MAGYAR
БЪЛГАРСKN
SRPSKI
HRVATSKI
SVENDKA
NORSK
SUOMI
DANSK
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - AIR CONDITIONER

P/NO : MFL67798017www.lg.comOriginal instructionINSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing

Page 2 - IMPORTANT SAFETY INSTRUC

10ENGLISH1 Always use the nitrogen.(not use oxygen, carbon dioxide, anda Chevron gas): Please use the following nitrogen pressure0.02MPa Oxygen – Pro

Page 3 - TABLE OF CONTENTS

11ENGLISH- Pipe connections can be done on the front side or on the side accord-ing to the installation environments.- Be sure to let 0.2kgf/cm2Nitrog

Page 4 - INSTALLATION PROCESS

12ENGLISHTotal pipe length = A+B+C+D+a+b+c+d+e ≤ 300mLLongest pipe length Equivalent pipe length(*)A+B+C+D+e ≤ 150m A+B+C+D+e ≤ 175mlLongest pipe leng

Page 5 - Air inlet grille

13ENGLISH• * : Assume equivalent piping length of Y branch to be 0.5m, thatof header to be 1m, calculation purpose• Indoor Unit should be installed at

Page 6 - 500 or less

14ENGLISHIndoor Unit ConnectionIndoor Unit connecting pipe from branch (a,b,c,d,e,f)Indoor Unit capacity[kW(Btu/h)]Liquid pipe[mm(inch)]Gas pipe [mm(i

Page 7 - Secure minimum intake area

15ENGLISH1st1st1stMain pipeDistribution2nd2nd3rd3ndMain pipeDistribution1st3rd3rd main pipe distribution2ndHorizontal Distribution• When the number of

Page 8 - INSTALLATION

16ENGLISH• Joints between branch and pipe should be sealed with the tape in-cluded in each kit.• Any cap pipe should be insulated using the insulator

Page 9 - R=0.4~0.8

17ENGLISHNOTE!If the ambient temperature differs between the time when pressure isapplied and when the pressure drop is checked, apply the followingco

Page 10 - Nitrogen substitution method

18ENGLISHBe sure to give insulation work to refrigerant piping by covering liquidpipe and gas pipe separately with enough thickness heat-resistant pol

Page 11 - Liquid/Gas pipes

19ENGLISH2-Core Shield CableMulti-Core CableRemotecontrolRemotecontrolRemotecontrolRemotecontrolIndoorUnitOutdoor UnitOutdoor UnitIndoorUnitIndoorUnit

Page 12 - Y branch method

2ENGLISH• Do not cool excessively indoors. This may be harmful for your healthand may consume more electricity.• Block sunlight with blinds or curta

Page 13

20ENGLISHNOTE!• The figures are based on assumed length of parallel cabling upto 100m. For length in excess of 100m the figures will have tobe recalcu

Page 14 - Refrigerant charging

21ENGLISHMasterOutdoor UnitSODU. B SODU. A IDU. B IDU. A CEN. B CEN. A DRY1 DRY2 GND 12V34 34 34[Heat Pump]Between Indoor and Master Outdoor uni

Page 15 - Horizontal plane

22ENGLISH- About more information of IO Module, please refer to IO Modulemanual.CAUTIONBe sure to turn off outdoor unit power before installation.!++※

Page 16 - Y branch pipe

23ENGLISHExample) Group number setting 1stnumber indicate the group number2nd number point out indoor unit numberSODU.B SODU.A IDU.B IDU.A CEN.B CEN.A

Page 17 - Gas side

24ENGLISHCAUTION• Request installer to set the function during installation. • If ODU RPM changes, cooling capacity may go down.!Master unit PCB DIP s

Page 18 - ELECTRICAL WIRING

25ENGLISHError No. of CompressorError No.Error No. of UnitRepeatDisplay Title Cause of ErrorIndoor unit related error0 1 -Air temperature sensor of in

Page 19 - Side panel

26ENGLISHDisplay Title Cause of Error5 0 1Omitting connection of R, S, T power of Outdoor Unit Omitting connection of outdoor unit5 1 1Excessive capac

Page 20 - 50Hz 380~415V 220~240V

27ENGLISHCalculate minimum room capacityCalculate room capacity by regarding a portion as one room or thesmaller room.- With partition and with openin

Page 21 - Outdoor Unit

CAUTION• Air conditioners should not be installed in areas wherecorrosive gases, such as acid or alkaline gas, are produced.• Do not install the produ

Page 22 - Automatic Addressing

[Representative] LG Electronics Inc. EU Representative Krijgsman 1, 1186 DM Amstelveen, The Netherlands[Manufacturer] LG Electronics Inc. Changwon 2nd

Page 23 - B(D) A(C)

3CAUTIONInstallation• Always check for gas (refrigerant) leakage after installation or repair of product.- Low refrigerant levels may cause failure of

Page 24

4ENGLISHThe foundation must be level evenOutdoor unit foundation workAvoid short circuits and ensure sufficient space is allowed for serviceInstallatio

Page 25 - Self-Diagnosis Function

5ENGLISHAir inlet grille700[Unit : mm]Turn the air outlet side toward thebuilding's wall, fence or windbreak screen.WARNINGFix the outdoor unit f

Page 26

6ENGLISHIn case of obstacles on the discharge side1. Stand alone installationa500 or lessmore1,000 ora2. Collective installation1,000 or more100 ormor

Page 27 - Smallest

7ENGLISHSeasonal wind and cautions in winter• Sufficient measures are required in a snow area or severe cold areain winter so that product can be oper

Page 28 - Product information

8ENGLISH• Fix the unit tightly with bolts as shown below so that unit will not falldown due to earthquake or gust.• Use the H-beam support as a base s

Page 29

9ENGLISHFlaring work- Carry out flaring work using flaring tool as shown below.Firmly hold copper tube in a bar(or die) as indicated dimension in thet