LG RV1329A7S User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
34
Part 5 PROGRAMMING MODE -
Test Mode
Data NameMachine
Entering
the test mode
CARD
/COIN
OPL
1. Entering programming mode
2. WHITES & COLORS
3. START
Insert service card (card type), Turn on/off toggle switch (Coin type).
Press the WHITES & COLORS button.
Then appears in the display.
Enter the diagnostic test mode.
Button Display Description
Entering the test mode
Diagnostic tests : (display)
This program has been added for testing the dryer and detecting errors.
11
Pressing the START button cycles to the next test function.
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use .
Note
Number of times the START
button is pressed
Display
Checking point
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
During check, if the door is open.
During check, if the door is closed
Check the version and code of machine.
ELECTRIC COIN TYPE : AU:OE
ELECTRIC OPL TYPE : CA:PE
GAS COIN TYPE : AU:Og
GAS OPL TYPE : CA:Pg
PDA CHECK
Motor runs.
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2250W)
GAS TYPE: GAS valve runs.
Motor + Valve
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2250W) + Heater 2 (2250W)
GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press WHITES & COLORS button.
Press PERM. PRESS button.
Press DELICATES button.
Press NO HEAT button
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven times)
Test goes back at step 2.
(Motor on & Heater Off)
LqC 1
Version and code of machine (All LED on)
COIN machine displays AU:OE or AU:Og and gU:XX
alternately. OPL machine displays CA:PE or CA:Pg and gU:XX
alternately. XX is the version number
Ir--
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in °
Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in °
Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door completely)
Measured moisture value (70~239)
1. Entering programming mode.
2. WHITES & COLORS
3. START
Push and hold the WHITES & COLORS and DELICATES at the same time.
After that push PERM. PRESS button for 3 times. Push START button.
Press the WHITES & COLORS button.
Then appears in the display.
Enter the diagnostic test mode.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 47 48