OWNER’S MANUALAIR CONDITIONER Please read this manual carefully before operatingyour set and retain it for future reference.TYPE : WALL MOUNTEDP/No. M
Electrical Safety• This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded outlet.• Do
Using the remote controlYou can operate the air conditioner more conveniently with the remote control. Wireless remote controlUsed to circu-Air Circul
12BASIC FUNCTIONSCooling your room(Cooling operation)1 Press to turn on the power.2 Press repeatedly to select the coolingoperation.- is display
13Adjusting the air flow direc-tion1 To adjust the direction of the flow verti-cally, press change the air flow direc-tion automatically.- This func
142 Press or to select . 3Press to finish.Turning on the air conditioner auto-matically at a set time1 Press - The icon below flic
15ADVANCED FUNCTIONSThe air conditioner offers some additional ad-vanced functions.Changing room temperaturequicklyH’COOL(Himalaya)ModeThis mode allow
16ADVANCED FUNCTIONSAuto operation (Optional)(Artificial inelligence)1Press to turn on the power.2Press repeatedly to select auto operation.3Pr
17ADVANCED FUNCTIONSOpen the frontpanel upwardON/OFFbutton(Forced Operation)HeatpumpModelCoolingModelRoomTemp.³24°C 21°C³RoomTemp.<24°C
MAINTENANCE18Micro Protection filterMicro Protection filter.1Use soap solution to clean the heat exchanger coils and the panel vents (consult with tec
MAINTENANCE19Plz do not press themesh with finger asshown above Caution :
(Recommended 24°C is suitable for human body)(Refer page no. 20 and 21 for details)
MAINTENANCE20Cleaning the Micro Protection Filter(Optional)cleaning the Micro Protection FilterMicro Protection Filter.We suggest changing the Micro P
TROUBLESHOOTING21call call call call
TROUBLESHOOTING22Operate the air conditioner on Air circulationmode (Refer to page 23) for 2 to 3 hours.• This will dry out the internal mechanisms.Wh
DISCLAIMER23IMPORTANT: Long term effect not tested and mosquitoes may become resistant. Mosquito species used in the test below may differ from the mo
20INSTALLATION- Do not use sea water for this purpose.
TEST RUNNINGBoltTubing connectionCheck that all tubing and wiring have beenproperly connected.Check that the gas and liquid side service valvesare ful
Gas sideLiquid sideCapHexagonal wrench2-way valve(Open)3-way valve(Close)CEvacuationSoap water methodRemove the caps from the 2-way and 3-wayvalves.Re
Lo HiIndoor unitOutdoor unitManifold valveCharge hoseNitrogen gascylinder(in verticalstanding position)PressuregaugeAir purgingPressure in the system
Tip of drain hose dipped in waterWaterleakageDitchLess than 50mm gapChecking the drainageDo not make drain piping.Form the pipingDo not raiseWaterleak
CONNECTING THE CABLEBETWEEN INDOOR & OUTDOOR UNITConnect the cable to theoutdoor unitARemove the control cover from the unit byloosening the screw
CONNECTING THE CABLEBETWEEN INDOOR & OUTDOOR UNITConnect the cable fromIndoor to outdoor unit.Connect the cable to the indoor unit byconnecting th
FLARING WORK AND CONNECTION OF PIPINGBundle the piping and drain hose together bywrapping them with cloth tape over the rangewithin which they fit int
Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipePlastic bandsInsulation materialVinyl tape(nar
Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipeDrain pipeConnecting cableWrap with vinyl tape
FLARING WORK AND CONNECTION OF PIPINGConnection of piping-IndoorPreparing the indoor unit's piping and drainhose for installation through the wal
Outside diametermmø6.35ø9.52ø12.7ø15.88ø19.05inch1/4"3/8"1/2"5/8"3/4"mm mm1.1~1.3 0.71.5~1.7 0.81.6~1.8 0.81.6~1.81.9~2.1 1.0
Mount the installation plate horizontally byaligning the centerline using a level.AMount the installation plate on the wall withfour type A screws. If
INSTALLATION OF INDOOR & OUTDOOR UNITRead completely, then follow step by step.Capacity is based on standard length and maximumallowance le
123456789101112Installation ToolsS.No. Required ToolsLevel GaugeScrew DriverElectric DrillHole Core Drill (Dia-70mm)Flaring Tool SetSpecified torque w
Type ‘A’ ScrewINSTALLATION PARTSInstallation parts provided with the unitType ‘A’ Screw Quantity Shape OthersType ‘A’ Screw Quantity Shape Others5Inst
/ TABLE OF CONTENTS5 Installation Parts provided with the Unit5 Installation Parts you must purchase6 Required ToolsINSTALLATION PARTS5791010111314161
(Recommended 24°C is suitable for human body)(Refer page no. 21 and 22 owner's manual)
INSTALLATION MANUALAIR CONDITIONER TYPE : WALL MOUNTEDPlease read this installation manual completely before installing the product.When the power cor
For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent thatcauses corrosion or damage on the unit. Ha
Disposal of your old appliance (as per e-waste Rules)1. When this crossed out wheeled bin symbol is depicted on the product and its operator’
– Prior to operationComponents– Electrical Safety– Using the remote control– Inserting BatteriesInstalling the remote control holderWireless Remote Co
Prior to OperationPreparing for Operation1. Contact an installation specialist for installation.2. Plug in the power plug properly.3. Use a ded
ComponentsSymbols used in this ManualThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to th